User's Manual Part 6

Page 7-44
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
KANDU
(06)
ASC (01) 0x 0001 DSP fault Hardware faults and events:
- Replace the KANDU.
0x 0020 ASC 1.2 V: Out-of-spec
0x 0021 ASC 1.5 V: Out-of-spec
0x 0022 ASC 1.8 V: Out-of-spec
0x 0023 ASC 2.5 V: Out-of-spec
0x 0024 ASC 3.3 V: Out-of-spec
0x 0025 ASC 5.0 V: Out-of-spec
0x 0026 ASC 12 V input: Out-of-spec
0x 0027 ASC 1.2 V current: Out-of-spec
0x 0028 ASC 1.5 V current: Out-of-spec
0x 0029 ASC 1.8 V current: Out-of-spec
0x 002A ASC 2.5 V current: Out-of-spec
0x 002B ASC 3.3 V current: Out-of-spec
0x 002C ASC 5 V current: Out-of-spec
Power supply
unit (02)
0x 0000 Power supply out of regulation
ASC BITE
EMIFA (11)
0x 0000 EMIFA unresponsive
0x 0001 EMIFA incorrect data
0x 0002 EMIFA OK
0x 0003 EEPROM unresponsive
0x 0004 EEPROM Incorrect Data
0x 0005 EEPROM OK
ASC BITE A429
IRS (12)
0x 0000 ARINC 429 IRS post unresponsive
0x 0001 ARINC 429 IRS incorrect data
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action