User's Manual Part 6

Page 7-45
3 Mar 2017
23-15-29
SYSTEM DESCRIPTION AND INSTALLATION MANUAL
JetWave™ System
© Honeywell International Inc. Do not copy without express permission of Honeywell.
KANDU
(06)
ASC BITE A429
IRS (12)
0x 0002 ARINC 429 IRS post OK Hardware faults and events:
- Replace the KANDU.
ASC BITE A429
AUX (13)
0x 0000 ARINC 429 AUX post unresponsive
0x 0001 ARINC 429 AUX incorrect data
0x 0002 ARINC 429 AUX post OK
ASC BITE
Ethernet switch
(14)
0x 0000 Ethernet MDIO unresponsive
0x 0001 Ethernet MDIO unexpected data
0x 0002 Ethernet MDIO OK
Temperature
Multiple LRU
(F9)
0x 0001
thru 0x
007F
Unique per temperature sensor with
LRU
Operational
information (FA)
0x 0000 Mode Transition Info events - Recording what
happened in the LRU.
0x 0001 Parameter
0x 0002 Event
0x 000A Standard electronic information
0x 000B Honeywell electronic information
0x 000C Subassembly information
0x 0080 Auto Alignment Pass
0x 0081 Auto Alignment Start
0x 0082 Auto Alignment Fail Incorrect Modes
0x 0083 Auto Alignment in Progress
0x 0084 Auto Alignment Solution Check Pass
0x 0085 Auto Alignment Solution Check Fail -
Heading
0x 0086 Auto Alignment Solution Check Fail -
Pitch
0x 0087 Auto Alignment Solution Check Fail -
Roll
0x 0088 Auto Alignment Solution Check Fail -
RF%
Table 7-6. L3 Codes (Continued)
L1 L2 L3 Code L3 Description Repair Action
Draft as of 31 May 2017