Users Manual Part 3
Table Of Contents
- 3. System Fails Post-Installation Checks
- 4. Incorrect Navigation Data
- 5. System Will Not Connect to the Network
- 6. Connectivity of Each Ethernet Port
- SECTION 7 – MAINTENANCE AND REPAIR
- 1. Maintenance Requirements
- 2. Continued Airworthiness, FAR 25.1529
- 3. Airworthiness Limitations
- 4. General Instructions for Inspection
- 5. Electrical and Mechanical Inspection and Check
- 6. Instructions for Continued Airworthiness
- 7. Visual Inspection and Check
- 8. Scheduled Maintenance and Inspections
- 9. Unscheduled Maintenance
- 10. Repair Requirements
- APPENDIX A – ENVIRONMENTAL CHARACTERISTICS
- APPENDIX B – INFORMATION SHEETS
- 1. Aircraft Information Sheet
- 2. JetWave™ MCS-8562 Terminal AES Subsystem Components
- A. JetWave™ MCS-8562 Terminal AES OAE - FMA Installation Information Sheet
- B. JetWave™ MCS-8562 Terminal AES KANDU Installation Information Sheet
- C. JetWave™ MCS-8562 Terminal AES BUC-HPA Installation Information Sheet
- D. JetWave™ MCS-8562 Terminal AES Modman Installation Information Sheet
- E. JetWave™ MCS-8562 Terminal AES APM Installation Information Sheet
- APPENDIX C – CHECKLISTS
- APPENDIX D – CUSTOMER PORTAL
- 1. Customer Portal
- 2. APM Request Form
- A. Requester Name
- B. Requester Email
- C. Honeywell Representative Name
- D. Hon Representative Email
- E. PO Number
- F. DP/VAR/Customer Name
- G. DP/VAR/Customer Name Contact Name
- H. DP/VAR/Customer Name Contact Email
- I. Channel Partner/Integrator/STC
- J. Estimated APM Due Date
- K. Aircraft Make / Aircraft Model
- L. Aircraft Model Variant
- M. Additional Notes/Comments
- 3. APM Parameter File
- 4. Request Assistance
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Dataload the Proper
APM for the installCritical Faults
Configuration
parameter
missing
3
Software
Configuration
FDModMan1
Dataload Modman
SoftwareCritical Faults
Primary Image
Corruption
Warning
4
Software
Configuration
FDModMan1
Dataload Modman
SoftwareCritical Faults
LRU PRI-SEC
Image
Mismatch
6
Software
Configuration
FDModMan1
Status
Message
A615A
DataLoad
7
Software
Configuration
FDModMan1
Status
Message
Data Loader
Connected
8
Software
Configuration
FDModMan1
Status
Message
Data Loader
Disconnected
9
Software
Configuration
FDModMan1
Status
Message
Operating
Image List
A
Software
Configuration
FDModMan1
Status
Message
Secondary
Image
Corruption
Warning
B
Software
Configuration
FDModMan1
Status
Message
OTA Staged
Software
DataLoad
C
Software
Configuration
FDModMan1
Mismatch between
APM and provisioned
setting
Status
Message
VLAN
MAPPING TO
SPECIFIC
PORTS
DISALLOWED
40
Software
Configuration
FDModMan1
Dataload APM
configuration files. If
JW1 system, also
contact service
provider
Warning
VLAN
TAGGING
MISMATCH
41
Software
Configuration
FDModMan1
Re-run cable
calibration. For
Modman x.5
(ChinaSat) If problem
with running cable
calibration, reload TM
configuration files
Warning
Missing
Transmit Cable
Calibration Data
50
Software
Configuration
FDModMan1
Page 6-22
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave™ MCS-8562 Terminal