Users Manual Part 3

Table Of Contents
Table 6-1. L1, L2 and L3 Codes (Cont)
Repair actionLog type
L3L2L1
DescriptionCode
Descrip-
tion
Code
Descrip-
tion
Code
Status
Message
ARINC 429 IRS
POST OK
2
ASC BITE
A429 IRS
12KANDU6
If problem persist
across power cycle,
replace the KANDU
Critical Faults
ARINC 429
AUX POST
UNRESPONSIVE
0
ASC BITE
A429 AUX
13KANDU6
If problem persist
across power cycle,
replace the KANDU
Note: this can be a
false positve
Critical Faults
ARINC 429
AUX
INCORRECT
DATA
1
ASC BITE
A429 AUX
13KANDU6
Status
Message
ARINC 429
AUX POST OK
2
ASC BITE
A429 AUX
13KANDU6
If problem persist
across power cycle,
replace the KANDU
Critical Faults
Ethernet MDIO
Unresponsive
0
ASC BITE
Ethernet
Switch
14KANDU6
If problem persist
across power cycle,
replace the KANDU
Critical Faults
Ethernet MDIO
Unexpected
Data
1
ASC BITE
Ethernet
Switch
14KANDU6
Status
Message
Ethernet MDIO
Ok
2
ASC BITE
Ethernet
Switch
14KANDU6
Status
Message
successful login3
LRU SFTP/
SSH
E2KANDU6
Status
Message
failed login4
LRU SFTP/
SSH
E2KANDU6
Allow KANDU to cool
to below 90 degreeCritical Faults
ASC Main
Temperature
Sensor
1
Temperature
of LRU's
F9KANDU6
Allow KANDU to cool
to below 90 degreeCritical Faults
KANDU PSU
Remote
Temperature
2
Temperature
of LRU's
F9KANDU6
Status
Message
Mode Transition0
Operational
Information
FAKANDU6
Status
Message
Parameter1
Operational
Information
FAKANDU6
Status
Message
Event2
Operational
Information
FAKANDU6
Status
Message
Standard
Electronic
Information
A
Operational
Information
FAKANDU6
Page 6-38
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal