Users Manual Part 3

Table Of Contents
and other maintenance required under sections 433.16 and 91.403 of the Federal Aviation
Regulations unless an alternative program has been FAA approved.
Initial and recurring inspections of the JetWave MCS-8562 Terminal AES OAE assembly and
LRUs and its associated provisions are required. Specific inspection intervals are contained in
Table 7-1.
4. General Instructions for Inspection
This section provides general instructions for the inspection of the JetWave MCS-8562 Terminal AES
OAE assembly and LRUs.
A. Gain access to the installation location on the fuselage for fuselage mount antenna assembly
B. Clean all visible surfaces of the antenna, radome assembly, and base plate.
C. Do the inspections and checks presented in Electrical and Mechanical Inspection and Check.
D. Remove the primary AC power delivered to the KANDU via aircraft circuit breaker. This will power
down the KANDU, including the 38.5 VDC and the 24 VDC power supply to the FMA.
E. Wait 1 minute following the removal of power to KANDU before attempting cable disconnect from
FMA, or any physical contact with the FMA.
F. In case of FMA, disconnect FMA Plug P1 and measure the voltage across Pin A and Pin B using
a voltmeter (38.5 VDC voltage line). The measurement should not exceed 1 VDC.
G. In case of FMA, disconnect FMA Plug P3 and measure the voltage across Pin 5 and Pin 6 using
a voltmeter (24 VDC voltage line). The measurement should not exceed 1 VDC.
5. Electrical and Mechanical Inspection and Check
Periodic inspections of the mechanical and electrical interfaces of the JetWave MCS-8562 Terminal AES
OAE assembly and LRUs to the aircraft should be completed as defined by the governing airworthiness
body (such as Transport Canada, the FAA, or the JAA) Instructions for Continued Airworthiness for the
installation.
For the general guidelines refer to Visual Inspection and Check and Scheduled Maintenance and Inspections
sections.
6. Instructions for Continued Airworthiness
This section supplies the special instructions and maintenance requirements for continued airworthiness
of the JetWave MCS-8562 Terminal AES subsystems.
JetWave MCS-8562 Terminal AES OAE assembly and LRUs are considered On-Condition units. No
additional or routine maintenance is required for the on-condition JetWave MCS-8562 Terminal AES
OAE assembly and LRUs.
If a JetWave MCS-8562 Terminal AES OAE assembly or an LRU is inoperative, do as follows:
- Collar applicable switches and circuit breakers
- Secure cables and wiring
- Remove the unit
- Placard the JetWave MCS-8562 Terminal AES LRU and associated items as inoperative in
accordance with the Aircraft Maintenance Manual (AMM)
- Before flight, do as follows:
Page 7-2
23-15-84
EFFECTIVITY
ALL
11 Nov 2020
© Honeywell International Inc. Do not copy without express permission of Honeywell.
SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
JetWave MCS-8562 Terminal