User's Manual

CI Wireless Inc. 1211 Ira E Woods Ave 32
Tel: 817 416 0583 Grapevine, TX 76051
700-1006-x2x 28VDC Power Supply + DC Distribution
Input Connectors
J1 - 28VDC @ 10 Amps output, connects to Power Amplifier + LNA/Driver modules
PINS 1 28 VDC
2 28 VDC
3 Ground
4 Ground
J2 - AC Input,
PINS 1 Line
2 Neutral
3 Chassis Ground
J3 - DC Input, Battery back up.
PINS 1 Ground Input
2 28 VDC
3 Control
4 28 VDC
J4 - 9 Pin D-sub Connects to 700-1004 Via 10 Conductor Ribbon Cable
J5 - Power Amplifier control signal inputs Direct connections to power Amplifier or to Fan Control
Module on units with heat exchangers.
J6 - 12 VDC Output, Connects to Fan Control Module.
PINS 1 Ground
2 Ground
3 12 VDC
4 12 VDC
LEDs
LED 1 - Red, Primary power on, 28 VDC from power supply selected
LED 2 - Yellow, Battery Back Up power on, 28 VDC Input selected
LED 3 - Green, Battery Back Up Enabled.
LED 4 - Red, 28 VDC From power supply present
LED 5 - Red, 28 VDC from Battery Back up present
Switches
SW1 - Switch, Primary Power on-off
SW2 - Switch, Enable Battery Back up
(Overrides auto selecting AC supply, allows battery backup to be checked by technician)
700-1008-XXX Fan Control/Alarm Module
Input Connectors
J1 - 10 conductor ribbon cable, IDC Connection to Power Amplifier - 9pin D-sub
J2 - 10 conductor ribbon cable, IDC Connection to Power Supply - IDC Connector
J3 - 10 conductor ribbon cable, IDC Connection to Heat Exchanger - 9pin D-sub
LEDs
D1 - Fan 1 on
D2 - Fan 2 on
D3 - Fan 3 on
D4 - Alarm - Fan
D5 - Alarm - PA Temp
VR1- Sets temperature when fans will turn on.
Pin 2 of u4A, 10 mVDC = 1 Fahrenheit. Example: 1.0 VDC = 100 F