User's Manual

CI Wireless Inc. 1211 Ira E Woods Ave 39
Tel: 817 416 0583 Grapevine, TX 76051
displayed, that menu screen MUST be changed (by pressing the MENU key) in order for
the change to take effect remotely. The display will now read “UL Updating Please
Wait..” When the update is complete the display will automatically change to reflect the
Value at which it is set. Due to network latency, it may take up to 20 seconds to change
the display. Setting the peak power limit is done here. The default is 34 or 38(depending
on the technology type), which will prevent the power out of the Pa to exceed 34 dBm or
39dBm. To exit this set of menus, press the MENU KEY.
TX 800Bse Pwr: XXXX Value corresponding to Power from Base Station to Hub unit
TX 800Lzr Pwr: XXXX Represents the power from the base to the dl laser
Or
TX 1.9Bse Pwr: XXXX Value corresponding to Power from Base Station to Hub unit
TX 1.9Lzr Pwr: XXXX Represents the power from the base to the dl laser
DL Pwr dB: XXXX Actual output power from PA at the antenna out of unit
UL Gain dB: XXXX The detected UL Signal strength at the hub
Peak Pwr SET: XXXX Refers to The Max Pwr Out the Unit will allow.
C. More Menus
By selecting ‘yes’ at the prompt, the user will have access to the following Menus. If not,
the menuing will loop back to the ‘Readings / Controls’ menu.
D. Maintenance Menu
This menu is used primarily for troubleshooting, maintenance and field calibration.
These readings are all network dependent, meaning that they only update when a
connection between the Hub and Microcell occur. If no connection is made then all
values found in this menu are invalid. The readings and their definitions are as follows:
Tx Pwr Lzr mV: XXXX The voltage returned from the detector to the
controller to u3. Helps to determine the TX pwr.
UL Gain Cntrl: XXXX The amount of UL attenuation at the Hub unit
UL RF Loss: XXXX The average amount of RF loss on the uplink path
UL Optc Los: XXXX The average amount of Optical Loss uplink path
UL Atten Set: XXXX Amount of direct Attenuation to the uplink path
** DL Rssi mV: XXXX Voltage returned from downlink Signal Strength
** DL RF Loss: XXXX The average amount of RF loss on the downlink path
** DL Optc Los: XXXX The average amount of Optical Loss downlink path
DL PA Detct: XXXX in mV the sensor output from the PA
DL dac mV: XXXX Voltage being put out by controller to the PA
Box Temp C: XXXX Tempeture in side the Remote unit in celcius
** = only available for the master remote unit.