8.2.4. ALARMS on HUB UNIT CONTROLLER
A. Viewing
To view alarms currently alarming simply press the F2 key from any menu, or if not
engaged in a menu, press F2 after pressing the ADD key. After viewing, press DEL to
return to normal functioning. Return to menu items by simply pressing the Menu key.
To view the alarm history log, first enter menus and press the menu key until the “Event
History…..View log?” Select Yes, using the Up or Down arrow and the menu key. The
alarms will be displayed in log format. Format consists of: Date, Remote Number and
Alarm. For example: 03-24-98 0 H! Optical 1. If the remote number is 0 then it must be
the hub.
B. Resetting
Hub: Press the F4 key form any menu. If not in menus press the ADD key then the F4
key. To resume Menuing or enter menus press the MENU key other wise press
the DEL key.
ALL: Press the F4 key WAIT 10sec then press the F4 key again (no need to wait on
second push). To resume Menuing or enter menus press the MENU key other
wise press the DEL key.
Microcells: This can be done only by engaging the menu system and going to the Reset
Alarms specific menu.
C. Alarms (current as of 12/30/98)
Hub: Alarms on the Hub unit will also display on any remote. Listing them:
!H Laser = Laser Alarm
!H Optical = Optical Loss Alarm
!H Prime Pwr = Primary Power
!H Com Link # = Communications Link #
!H Bs Pwr In = Insufficient Power from the base station.
!H User1 = User Alarm From External digital input