User's Manual

CI Wireless Inc. 1211 Ira E Woods Ave 65
Tel: 817 416 0583 Grapevine, TX 76051
Unit
Problem Check Corrective Action
Optical RX Check LED on Fiber Optic RX
Jumper Laser out to optical input
- if failed
Replace Fiber Optic Rx
OK Trouble Shoot Hub laser and/or
optical cable
Laser Alarm Check Fiber transceiver optical
power & LED
Replace Fiber transmitter
Laser Temp Check if housing temperature is
between -30° & 70°C
Replace fiber transmitter
PA Temp Alarm Check current draw, High -
check Housing temperature
Replace PA
RF Power Output Repeat Trouble shooting steps
under Hub section
Enclosure Temperature Alarm Check Housing Temp If ok - Replace 700-1004
No Up Link 1.9 GHz Signal Check Optical Path, Trouble shoot Optical Path
If ok - RF Signal test LNA, if fail Replace LNA
If ok - Test Duplexer , if fail Replace Duplexer
If ok - Test Polyphaser, if fail Replace Polyphaser
Intrusion Alarm Door Open Close Door
Defective Switch Replace Switch
No Power AC Fuse Replace
AC Power Alarm DC Fuse Replace
Disconnect DC Cable on AC
Power Output, Measure with volt
meter , Turn Off AC Power for
90 seconds, check again, if BAD
Replace Power Supply
Battery Back Up Alarm Check Back up DC source or
recharge, if bad
Replace battery and/or charger
unit