SET UID# User Name for User ID # (8 alpha-numeric)
SET DT Date in mm/dd/yy format
SET TM Time in 24hr format hh:mm:ss
SET ID Unit ID or Name
SET MUMNUMBER Phone Number to Dial to MUM when Report Active
SET UNTNUMBER Phone number of the Mirror Cell Unit.
SET REPORT Report Alarms (ON or OFF)
SET ALARM # Alarm # active or disabled (ON or OFF)
SET HB PERIOD Time between Expected Contact 0=HB off (0-999)minutes
SET ALRM RTRY Number of retries to send alarms. (0-100)
SET ALRM INTV Minutes between Alarm report retries.
SET DL FREQ # (Freq) Sets down link center frequency of the band pass
SET UP FREQ # (Freq) Sets uplink center frequency of the band pass
SET DL ATTN # Sets down link attenuation to a specified level
SET UL ATTN # Sets up link attenuation to a specific level
The example below shows how to set the repeater DL and UL passband center
frequencies (this example assumes that OPT-2 offering two non-adjacent operating
bands has been installed):
Example >set dl freq 1 1975.00
>set up freq 1 1895.00
>set dl freq 2 1947.50
>set up freq 2 1867.50
Note: ‘SET UL ATTN #’ and ‘SET DL ATTN’ commands override the auto setup
feature and allows the repeater to be set up outside of the RF detected power range of
the repeater. Peak power limit will still function properly at the lowest usable level of
detection (+18 dBm typical). The user may wish to disable down link power detect
alarm which will be on constantly due to no RF detected.
The RF detector has typically a dynamic range of detection of 23 dB and factory is
calibrated in the factory for a RF power range of +17 to +40 dBm. The software look
up table for the RF detector gives the unit a very accurate means of measuring
average RF output power, typically +/-1 dB across the power range. Greatest
accuracy is in the higher power ranges between +30 to +40 dBm.