User's Manual

EMS Wireless Operator’s Manual
MirrorCell II CDM 812, CDM1912 Series
608112-1, Rev C
37
PCS A
PCS B
PCS C
PCS D
PCS E
PCS F
1850 – 1865 MHz
1870 – 1885 MHz
1895 – 1910 MHz
1865 – 1870 MHz
1885 – 1890 MHz
1890 – 1895 MHz
1930 – 1945 MHz
1950 – 1965 MHz
1975 – 1990 MHz
1945 – 1950 MHz
1965 – 1970 MHz
1970 – 1975 MHz
Bandwidth of Bandpass 800 MHz Models: 200
kHz – 14 MHz
1900 MHz Models: 200
kHz – 15 MHz
800 MHz Models: 200
kHz – 14 MHz
1900 MHz Models: 200
kHz – 15 MHz
Composite Output Power
Maximum Limit
+23dBm +/- 1 dB (200
mW)
+33 dBm +/- 1 dB (2W)
+36 dBm +/- 1 dB (4W)
(1900 MHz only)
+39 dBm + 0.5/-1.0 dB
(8W)
+43 dBm + 0.5/-1.0 dB
(20W)
Gain at Minimum Attenuation:
800 MHz:
1900 MHz:
+36 dBm (4W) option
+38.5 dBm (7W) option
+43 dBm (20W) option
(see next page)
90 dB Nominal for any
power output option
90 dB Nominal
92 dB Nominal
95 dB Nominal
(see next page)
90 dB Nominal for any
power output option
90 dB Nominal
92 dB Nominal
95 dB Nominal
Gain Range 30 dB 30 dB
Gain Flatness 2.5 dB pk to pk 2.5 dB pk to pk
Gain Change over temperature +/- 2 dB +/- 2 dB
Gain Step Size 1 +/- 0.5 dB 1 +/- 0.5 dB
Gain change over BW
+/- 2 dB +/- 2 dB
Number of Carriers
Single or Multiple Single or Multiple
Noise Figure at Maximum Gain
800 MHz:
1900 MHz:
<5 dB
<5 dB
<6.5 dB
<6.5 dB
Spurious Output FCC/IC FCC/IC
Number of Bandpasses or
Channels
1 or 2, depending on
option
1 or 2, depending on
option
Signal Electrical Delay
3 sec (Typical) 3 sec (Typical)
Connectors
N(f) Standard, DIN 7-16
Optional
N(f) Standard, DIN 7-16
Optional
Mean Time Between Failures
(MBTF)
75,000 hours 75,000 hours
Table 3: MirrorCell