Connect a laptop computer with a terminal emulator program (i.e.,
HyperTerminal, ProComm, etc.) to the MirrorCell
II RS232 port with a DB9
straight-through serial cable, as shown in Figure 7 below. The male connector is
attached to the repeater port and the female connector is attached to the laptop’s
RS232 serial port.
Figure 7: RS232 Port Location
Start the terminal program with settings 9600-8-N-1 and initialize the login by
pressing ‘enter’. Details of the terminal program configuration are shown in
Appendix A of this Operator’s Manual. Login to the repeater with your username
and password. The default username and password are “USERNAM1” and
“PASSWRD1” respectively, without the quote marks. Note that all software
commands are CASE SENSITIVE. Section 6 of this Operator’s Manual details
Interconnect