8.1.4. ALARMS on MICROCELL UNIT CONTROLLER
A. Viewing
To view alarms currently alarming simply press the F2 key from any menu, or if not
engaged in a menu press the ADD key then press F2. After viewing, press DEL to return
to normal functioning. To return to menu items simply press the Menu key. To view the
alarm history log, enter menus and press the menu key until the “Event History…..View
log?” is displayed, then select Yes using the Up or Down arrow and enter by pressing the
menu key. The alarms will be displayed in log format. Format consists of: Date Remote
Number and Alarm. For example: 03-24-98 0 H! Optical 1. If the remote number is 0
then it must be the hub.
B. Resetting
Local: Press the F4 key form any menu. If not in menus press the ADD key then the F4
key. To resume menuing or enter menus press the MENU key other wise press
the DEL key.
Hub: Press the F4 key WAIT 10 seconds then press the F4 key again (no need to wait
on second push). To resume Menuing or enter menus press the MENU key other
wise press the DEL key.
C. Alarms
There are basically 12 alarms that could alarm at the Microcell unit. They are:
( # = Microcell Address)
!R# Laser = Laser Alarm
!R# Optical = Optical Loss Alarm
!R# Laser Temp = Laser Temperature
!R# Pa Temp = PA Temperature
!R# Box Temp = Box Temperature
!R# Intrusion = Door Alarm
!R# RF Pwr Out = RF Output Power Fail
!R# Ovrdr Pwr Aj = Overdriving Power Adjustment.
!R# Batt Power = Low or No Battery (only seen if Battery Enabled)
!R# Main Power = Drop or failure of Main power.
!R# Fan Fail = Fan Failure or Problem
!R# User 1 = User 1 Hi/Lo from D6 On Remote Board