User's Manual

EMS Wireless Operator’s Manual
EkoLink II
34
default. These are false alarms and it will be necessary for the user to
disable these unused channels to clear the alarms.
The command to disable the unused channels is:
2>set fiber <n> = disabled
Where n corresponds to the desired channel. In the event that the wrong
channel is inadvertently disabled or a remote is added at a later time the
disable channel should be enabled using the following command.
2>set fiber <n> = on
where n corresponds to the desired channel.
2.9.4 Offsets
Under normal conditions, the factory default power settings are configured to
provide +20 dBm output power at each remote. The factory settings will
provide optimum performance in most environments; however the user has
the option to change the power settings in each remote according to
individual requirements.
Set an “offset” to the default value for the desired remote. For example, to
set remote 1 to +18 dBm type:
2>set remote 1 = -2
The range for the offsets is –10 dB to +0 dB and can only be set in 1 dB
increments. In this way, each remote can be tuned to the user’s specific
requirements after the system is deployed.
To verify the offsets for each remote the following command may be used:
2> get remote n
where n is the number of the specific remote offset requested.
3.0 Maintenance
The EkoLink II system is designed to be virtually maintenance free for the
user.