User's Manual

EMS Wireless Operator’s Manual
EkoLink II
37
PARAMETER DOWNLINK UPLINK
30kHz BW
200kHz BW
P
out
=+9dBm
64 dB
56 dB
---
---
Sensitivity for 200kHz BW for
BTS S/N of 9dB
--- -98 dBm
Sensitivity for 1.25MHz BW
for E
b
/N
o
of 7dB and 14.4kHz
data rate
--- -111dBm
SFDR in 200kHz BW 53 dB 61 dB
Propagation Delay
<0.5 µs (RF) +
5 µs/km,typ (fiber)
<0.5 µs (RF) +
5 µs/km,typ (fiber)
Impedance
50 50
Input/Output VSWR <1.5:1 <1.5:1
Hub RF Connector N-type N-type
Remote RF Connector N-type N-type
Optical Connector SC/APC SC/APC
Optical Fiber
9/125 µm (core/clad)
1310 nm, singlemode
9/125 µm (core/clad)
1310 nm, singlemode
Wavelength 1310 nm 1550 nm
Table 2. Link Performance specifications.
4.2 User Requirement Specifications
Table 3 shows requirements that the user must satisfy for proper operation of
the EkoLink II system.
PARAMETER USER REQUIREMENT
Max Composite RF Input
(damage level)
+30 dBm (downlink)
+10 dBm (uplink)
Max Optical Fiber Length 10 km
Optical Fiber
9/125 µm (core/clad)
1310 nm, singlemode
Optical Connectors SC/APC
Optical Return Loss
40 dB
Number of Optical Fibers One per remote unit
Chassis AC Power
(factory configured)
90 to 135 VAC or 184 to 264 VAC
50-60 Hz
Backup Power Supply
+12 VDC ± 0.5 V, 8.5 A max load