User's Manual

EMS Wireless Operator’s Manual
EkoLink II
8
flash on power-up. If the check value does not agree, then
the default settings are used.
2.9.2 Command Structure
There is an extensive user help menu available to the user and a separate
software command reference manual. The basic format for all the
commands is:
<Primary-Command> <Secondary-Command> = <setting>
All commands are made up of this generic format; in some cases, there is no
setting or secondary command. The command set is basically a tree
diagram, where typing in the primary (and optionally secondary) command
with the setting result in a change in the module’s operational parameters.
All input is case-insensitive for commands. For example:
set laser 1 = on
This command would turn the laser #1 on at the present potentiometer
setting stored in memory.
2.9.3 Remote Alarm Disabling
From the factory, the Hub is programmed to alarm any time a Remote is
disconnected from the Hub. This safety feature is designed to indicate such
catastrophic events as the fiber to the Remote being cut. For a Hub that
does not use all four channels, the unused channels will report an alarm by
default. These are false alarms and it will be necessary for the user to
disable these unused channels to clear the alarms.
The command to disable the unused channels is:
2>set fiber <n> = disabled
Where n corresponds to the desired channel. In the event that the wrong
channel is inadvertently disabled or a remote is added at a later time the
disable channel should be enabled using the following command.
2>set fiber <n> = on