where n corresponds to the desired channel.
2.9.4 Offsets
Under normal conditions, the factory default power settings are configured to
provide +20 dBm output power at each remote. The factory settings will
provide optimum performance in most environments; however the user has
the option to change the power settings in each remote according to
individual requirements.
Set an “offset” to the default value for the desired remote. For example, to
set remote 1 to +18 dBm type:
2>set remote 1 = -2
The range for the offsets is –10 dB to +0 dB and can only be set in 1 dB
increments. In this way, each remote can be tuned to the user’s specific
requirements after the system is deployed.
To verify the offsets for each remote the following command may be used:
2> get remote n
where n is the number of the specific remote offset requested.