User's Manual

EMS Wireless
EMS Wireless EkoMini Manual
15
detectable level. A quick check can be made by getting within a few feet of the Rerad
Antenna, while watching the Uplink RF indicator.
Primary Power
The EkoMini Unit operates on 9 VDC input power @ 6 Amps. This is supplied with a
regulated wall mount supply, which is UL and CSA listed. These are available to
operate on AC input voltages of 90 to 260 VAC.
Donor Antenna
This input/output is connected to an antenna, which is directed at the desired cell site.
Rerad Antenna
This input/output is connected to an antenna, which is mounted in the desired area to
be covered. The antenna should be mounted at a location where adequate coverage is
provided for the area desired while EkoMinimizing the potential of subscriber units
normally operating close enough to overdrive the unit.
Serial Number
Each unit has a unique electronic serial number. This number is displayed on the decal
on the unit and is also displayed with the history log when using the modem
interconnect.
Installation:
Note 1: Only qualified technicians should perform Installation and system set up. The
user is cautioned that modification or changes to this device not expressly approved by
the party responsible for compliance could void the user’s authority to operate this
equipment.
Note 2: Manufacturer’s rated output power of this equipment is for single carrier
operation. For situations when multiple carrier signals are present, the rating would
have to be reduced by 3.5 dBm, especially where the output signal is re-radiated and
can cause interference to the adjacent band users. This power reduction is to be
determined by means of input power or gain reduction and not by an attenuator at the
output device.
Note 3: This device complies with Part 15 of the FCC Rules. Operation is subject to
the condition that this device does not cause harmful interference.