Unpack all of the boxes and insure all of the material is included for your installation
requirements and undamaged in shipment.
EkoMini with IP Modem
QTY
Description
1 EkoMini
1 Manual
1 Test Data, Factory
Mounting
EkoMini is designed for optimum use as an in-door repeater. The housing is not weather
resistant and the automatic set up procedure assumes sufficient isolation between antennas is
assured. When the donor antenna is mounted outside and the rerad/server antenna is mounted
inside of a building isolation is assured to be adequate.
Antennas mounted outside shall comply with Article 810 of the National Electrical Code,
ANSI/NFPA 70, specifically, clearances from power and lightning conductors, mounting, and, if
necessary, groundings.
Since the EkoMini has a minimum gain of 40 dB, isolation of at least 55 dB must be obtained
between the donor and the rerad antenna. Should adequate isolation not be obtained an
oscillation could occur which could cause damage to the unit.
Connect coaxial cables to the Donor and Rerad ports.
Connect primary power module to unit
For EkoMini with IP Modem connect AC Power to AC Power Input on
Modem Module and connect 9VDC Output of Modem Module to EkoMini
DC Input.