User's Manual

Front Panel Operation 3-10
DataNex EMS Wireless, DATA-20 Digital Radio
Function Settings Summary
Cards Active RF RX A
DECDR 1
ENCDR 1
QAMOD A
RF TX A
MUX 0
CH CD 1
QAM Receiver RF Module installed in QAM Radio “A”
slots (base address 0)
Audio Decoder #1 installed (base address 1)
Audio Encoder #1 installed (base address 2)
QAM Modem Module installed in QAM Radio “A” slots
(base address 3)
QAM Transmitter RF Module installed in QAM “A” slots
(base address 4)
Intelligent Multiplexer #0 installed (base address 5)
Note: The card view screen gives the user a list of all installed cards in the unit. The base
address (B. Addr) is listed for diagnostic purposes only.
3.4.3 System: Power Supply
Power Supply Status
Primary
+5VD
+15VD
AC
5.00 V
15.00 V
Function Settings Summary
Primary
AC
DC
Indicates type of supply in primary slot A:
Universal AC input
DC Option
+5 VD 0-9.99 V
5.20 V nominal
Voltage level of the main +5 volt supply
+15 VD 0-99.9 V
15.2 V nominal
Voltage level of the main +15 volt supply
3.4.4 System: Info
System Information
Security
Firmware
USER
V.2.04
Unit No.
1
Function Settings Summary
Unit No. 1,2,3,… Identification for NMS system
SECURITY
Lockout
User (default)
Factory
Indicates access level of security:
No control available
Limited control of parameters
Full configure and calibration
FIRMWARE V x.xx Revision of front panel screen menu software