User's Manual

EMS Wireless Operator’s Manual
EkoLink Plus Fiber Optic DAS
25
Table 1: Default User Names and Passwords
User Name
Password Authority
USERNAM1 PASSWRD1 Read/write
USERNAM2 PASSWRD2 Read/write
USERNAM3 PASSWRD3 Read only
USERNAM4 PASSWRD4 Read only
Change the default Username and Password. Each Username and Password can have
a maximum of eight characters. For example, to change the second Username and
Password, enter the following two commands:
SET PWD#[password]<enter>
SET UID#[password]<enter>
Type ‘RESTART’ followed by the “enter” key. This command will re-set all the software
settings and allow the set-up routine to measure the RF signal levels and set the
attenuators appropriately.
Type ‘EXIT’ to log off the EkoLink Plus hub. Disconnect the RS-232 cable from the
hub.
3.1.2 Remote Set-up:
Move the computer and serial cable to each of the remote units. Log on to each
remote unit using the same procedure as above for the hub unit.
At each remote, look at the status screen. If necessary, adjust the peak RF output
level by using the SET PEAK command. For example,
SET PEAK 24
This command will set the RF output power to 1 dB less than the command value. In
this example, the RF output from the remote unit will be +23 dBm.
Type the RESTART command. This command should initialize the software
sequence, and set up the remote so it will transmit at the power level set in the
previous step.