User's Manual

EMS Wireless Operator’s Manual
EkoLink Plus Fiber Optic DAS
36
7.0 Detailed Software Commands
7.1 General
The Channelizer Module is equipped with a status and control system, which allows
the monitoring and control of various parameters such as channel number, attenuation,
temperature, status of door, etc., either with a local serial port/computer connection or
via the MirrorCell Unit Manager (MUM). The communication interface between the
computer and the control module is set up as a self-explanatory menu for simple
manual control and monitoring. This way, the parameters can be easily read off of and
set up from the display.
Note: The Usernames and Passwords should be changed during installation.
7.2 Software Command Set
A complete list of the manual software commands is shown in Table 6 below.
Table 6: Manual Software Command List
Command Range Example Description
General Commands:
GET PASSWORD Displays current Username
and Password settings.
NEED UPDATES Can be used to retrieve
information from the MUM
RESTART Allows the unit to re-initiate
the automatic software set-
up sequence.
INIT232 Initializes both serial ports
of the Channelizer.
GET FAT Displays all attenuation and
allocation thereof.
STATUS Displays Status Screen.
STAT Displays Status Screen.
HANGUP Causes the RS232 port to
sent ATH to the modem.
LIST ALARMS List alarms and if they are