The RF detector typically has a dynamic range of detection of 23 dB and is calibrated
at the factory for a RF power range of 17 to 40 dBm for the 8 watt unit option. The
software look up table for the RF detector gives the unit a very accurate means of
measuring average RF output power, typically +/-1 dB across the power range.
Greatest accuracy is in the higher 10 dB of the power ranges. For example, option 739
would have the greatest accuracy in the +30 to +40 dBm region.
Command Examples
>set ul offset 2
>set dlpower 34
>set protocol CDMA
>set peak 37
>set PWD2 pass2
>set UID2 user2
>set dt 20/02/01
>set dt 02/20/01 Date set.
>set tm 11:47:00 Time set.
>set id unit123
>set memnumber 9876543211
>set untnumber 1234567890
>set report on
>set alarm 1 off
>set hb period 21
>set alrm rtry 2
>set alrm intv 5
7.3 Communication via the MirrorCell Unit Manager
To establish a connection to the repeater, follow the instructions contained in the
MirrorCell Element Manager User’s Guide. To enable the repeater to dial into the MUM
to report ALARMS three command settings must be made.
1. SET UNTNUMBER – tells the repeater the phone number of the cell phone
assigned to it
2. SET MEMNUMBER – Tells the repeater what number to call when an alarm has
been triggered
3. SET REPORT ON – Tells the repeater that it is ok to report alarms when they occur
ALL setting commands can be administered by the MUM.