Instruction Manual
 BLU- CIF2 Interface Board 
BLU-CIF2 Cat5e Wiring Instructions 
IMPORTANT:  IF you are using CAT5e wiring termination with the 
BLU-CIF2, then the RJ-45 connectors need to be crimped to TIA/EIA 568B 
Standards (see below) on both ends of the cable. You must crimp and test 
the wiring with an approved CAT5 568A/B tester before connecting any 
cable between the BLU Products and the BLU-CIF2 Interface Board.  
Failure to crimp wiring to the correct standard could possibly lead to 
component damage. 
       EIA/TIA568B 
 1. White-Orange 
 2. Orange 
 3. White-Green 
 4. Blue 
 5. White-Blue 
 6. Green 
 7. White-Brown 
 8. Brown 
The BLU-CIF2 Interface Board 
simplifies the wiring of all of the BLU 
products to two BSS Audio London 
Series Digital Signal Processors. It 
allows for Cat5e wiring termination, 
as well as, termination to 3.5mm 
euro-style blocks. The BLU-CIF2 
accommodates connections for two 
BLU-CC, two BLU-CP, two BLU-
CS, up to five BLU-IR, or up to seven 
BLU-SV / BLU-SV8 plus Emtech 
MSC-C modules for providing audio 
in overflow areas. It is designed for 
mounting on the back door of a 19” 
rack. 