2 Installation Procedure
2.1 Battery Installation
Remove screw to open Control Panel battery case cover. Insert 6
NiCd AA batteries. Replace screw.
2.2 RJ31X Connector
Open the RJ31X connector to reveal eight screws.
Cut the main telephone cable.
Connect the red
strand of the main telephone cable (Net Ring) to the
red
wire inside the RJ31X connector.
Connect the green
strand of the main telephone cable (Net Tip) to
the green
wire inside the RJ31X connector.
Connect the yellow
strand of the main telephone cable (Telco Ring)
to the yellow
wire inside the RJ31X connector.
Connect the black
strand of the main telephone cable (Telco Tip) to
the black
wire inside the RJ31X connector.
Plug the short cable into the RJ31X connector.
Connect the red
strand of the main telephone cable (Net Ring) to the
Net Ring terminal on the terminal block (see Section 1.4 below).
Connect the green
strand of the main telephone cable (Net Tip) to
the Net Tip terminal on the terminal block (see Section 1.4 below).
Connect the yellow
strand of the main telephone cable (Telco Ring)
to the Telco Ring terminal on the terminal block (see Section 1.4
below).
Connect the black
strand of the main telephone cable (Telco Tip) to
the Telco Tip terminal on the terminal block (see Section 1.4 below).
2.3 Connectors J5 and J7
Connector J5 (marked on the Control Panel PCB) is an RJ11
connector. Connect it to the X-10 units in the system.