User's Guide

Page 6 of 46
Document # E.0015.16.02 406985
Message exchange: Short verbal messages may be
recorded by any user. On arrival, each user can
automatically receive any messages left for him. Messages
may also be collected by remote telephone.
Electrical device control: X-10 modules can be programmed
to control specific lights/appliances within the building.
Remote control from control panel, keyfob or telephone:
PGM (programmable) modules can be used to control gate
mechanisms, courtesy lighting and other devices outside the
building.
A DAA (Direct Access Arrangement) with capacitive coupling
to a DSP provide all PSTN functions including all pulse,
DTMF and FSK communication protocols. A 2400 baud fast
data transfer modem for remote programming. The DSP
includes Telephone Line Monitor (TLM) that monitors
continuously the status of the PSTN line.
Fully programmable control panel for a wide range of
security options.
The IntegrAlarm control panel meets the following SIA standards:
ANSI/SIA CP-01-2000 Control Panel standard – False Alarm
Reduction Feature Standard.
SIA DC-02 Digital Communication Protocols for SIA pulse
protocols P1, P2, P3, P4, SIA DTMF protocol and SIA FSK
protocols (Level 1 and partially Level 3)
SIA DC-05 Digital Communication – Ademco (R) Contact ID
Dialer Protocol Standard.
SIA AV-01 Audio Verification Standard.
1.3 Wireless Specifications
Operating frequency band – ISM 902-928 MHz.
Mode of operation – frequency hopping; every data packet is transmitted
on a different pseudo random selected frequency.