Adapters Troubleshooting and Maintenance Manual

Troubleshooting and Maintenance Manual for LightPulse Adapters Page 6
Incorrectly set configuration parameters. If the driver parameters are set incorrectly,
erratic behavior can occur such as very long failure timeouts, storage being overrun by
too many concurrent commands and failures in path management software that rely on
specific Emulex driver settings.
Incorrect target binding. If persistent binding is not correct, devices that are expected to
show in the OS storage management tool are not present.
Adapter management software
Management software package does not match the driver version. If the package does
not match the driver version, erratic behavior can occur with the management standard
HBA API, firmware downloads and functions of the HBAnyware utility. For best results,
use the HBAnyware utility version packaged with the driver.
OS SCSI stack drivers
Wrong OS patch level. An incorrect level can effect system performance. OS providers
often patch elements of the SCSI stack to correct problems and improve performance.
OS providers generally maintain a knowledgebase, search there if you are experiencing
a problem. OS patches can require coordinated changes in low-level device drivers from
the adapter makers to work properly. For example, Emulex specifies (on the Emulex
Web site and in Emulex documentation) what version of Microsoft's STORPORT.SYS is
required for a particular version of Emulex's Storport Miniport driver, ELXSTOR.SYS.
Path management software
Unsupported configuration. An unsupported configuration or incorrect SAN zoning and/
or configuration can result in unexpected behavior.
Unsupported adapter driver. An unsupported driver can result in software that does not
operate properly. Tight integration between software and drivers is critical. The correct
version of the driver must be used for proper operation.
Unsupported adapter driver configuration. Unsupported driver settings can result in
failovers that take too long or can be triggered unnecessarily (these problems can be
caused by incorrectly configured timers in the adapter driver). Correct settings in the
adapter driver specified by the path management software provider must be used.
Checklists
Connectivity Checklist
After setting up a new SAN or reconfiguring an existing SAN, connectivity problems occasionally occur.
Storage volumes (devices) may not appear in the OS, although the storage management tool is ready
for use. The devices could be marked offline or not present at all. Below is a checklist that can be used
to help solve connectivity problems.
Check for a good FC link. Verify that there is a good link at the desired speed. Most Emulex
adapters have LED lights that provide the link status and current speed of each port. The LED
states for each adapter are documented in each adapter's User Manual and are also available
at: www.emulex.com/ts/index.jsp If the LEDs are not visible, use the HBAnyware utility to show
link status or use the remote port's utility to examine the link state. For example, if the Emulex
adapter is connected to a switch port, use the switch's utility tools to see the link state.