User manual
The OneCommand Manager User Manual Page 105
Figure 60: Host Driver Parameters tab - Host Selected
5. Enter a new value in the Value field in decimal or hexadecimal format, depending on how the 
current value is presented. If the value is in hexadecimal format, it is prefaced by ā0xā (for 
example -ā0x2dā).
6. To make a change temporary (the parameter to revert to its last permanent setting when the 
system is rebooted), check Make changes temporary. This option is available only for dynamic 
parameters.
7. To make changes to multiple parameters, check Make all changes temporary. Only dynamic 
parameters can be made temporary.
8. Click Apply.
Changing Non-dynamic Parameter Values (Linux 8.2) 
To change non-dynamic parameter values for Linux version 8.2:
1. Navigate to the /usr/sbin/ocmanager directory and run the scripts to stop the OneCommand 
Manager application processes. Type:
./stop_ocmanager
2. Stop all I/O to LPFC attached devices.
3. Unload the LPFC driver. Type:
modprobe -r lpfc
4. Reload the driver. Type:
modprobe lpfc 