Product Card

Users’ Manual EAN-95MW Wireless Tilt meter
Page | 7
5 INSTALLATION PROCEDURE
5.1 Tilt meter installation
The EAN-95MW tilt meter (biaxial) is used to measure rotation of structures in the plane parallel as well
as perpendicular to the surface/wall on which the tilt meter is mounted.
The tilt meter box is provided with mounting holes as in figure below.
For installing the tilt meter on wall, mark locations of the four mounting holes. Ensure that position
of the holes are aligned vertically using a spirit level.
Drill holes depending on the mounting fasteners being used for fixing the tilt meter and fix the tilt
meter on wall ensuring its vertical position. (Do not close the box before configuring it.
Configuration details are given in next section)
5.2 Configuring tilt meter
Connect the Android smartphone to the ER_BeamWiFi network. (Refer to the users’ manualof
Gateway to learn about switching on the ER_BeamWiFi network.)
Mounting holes