Data Sheet

Table Of Contents
SET
SET
SET
d.PNt..= Display decimal point parameter
Decimal point can be adjusted between 1. and 3. digits.
See NOTE 1 for programming.
L.ScL..= Lower value of the scale.Adjustable between
(H.SCL.-10).
Scale the lower value of the output,based on o.typ.. parameter
selection, it is 0V,0mA or 4mA
See NOTE 1 for programming.
-1999 and
H.ScL..= Upper value of the scale.
Adjustable between (L.SCL.+10) and 9999.
Scale the upper value of the output based on, o.typ.. parameter
selection;it is 10V or 20 mA. H.SCL. and L.SCL. difference can
not be greater than 9999.
See NOTE 1 for programming.
Lo.Li..= The lower limit of the preset value.
Adjustable between L.ScL. and (Hi.Li.-10).
See NOTE 1 for programming.
Hi.Li..= The upper limit of the preset value.
Adjustable between (L.o.li.+10) and H.SCl.
See NOTE 1 for programming.
o.E.ty. = Adjusted type of the output to preset value with button.
dSAb.= Output can not be adjusted to preset value with button.
Enb. = Output can be adjusted to preset value with button.
S.on = Output is increased to voltage that set value is displayed with button during r.tI
See NOTE 1 for programming.
o.d.ty. = Adjusted type of the output to lower limit value with button.
dSAb.= Output can not be adjusted to lower limit value with button.
Enb. = Output can be adjusted to lower limit value with button.
S.oFF = Output is increased to voltage that lower limit value is displayed with button
during dtI.
See NOTE 1 for programming.
P.on.C. = Selection of the output parameter behavior
key is pressed while holding down to key
the programming mode is entered
r.ti. = Increasing time for output.
Adjustable between 1-250 seconds.Output is
increased slowly to the lower limit value
during adjusted time.
d.ti. = Decreasing time for output value.
Adjustable between 1-250 seconds.
Output is decreased slowly the lower limit
value during adjusted time.
See NOTE 1 for programming.
Pi.rt.. = Increasing and decreasing speed
of preset value.
It is adjustedI dSAb. ,1, 10,100 ve 1000
values. dSAb is selected,the preset value
can not be changed.
Selected according to the value increase or
decrease the preset buttons for fast switching
mode,the preset value speedy is increased or
decreased “one by one”,10 at each step,100
at each step,1000 at each step.
d.Adr.=Device address for ModBus.
Adjustable between 1-247 or selectable c.Pot. .When c.Pot. is
selected,the device will be master potentiometer and slave
potentiometers can be adjusted dependent on it.
See NOTE 1 for programming
This parameter is active device with RS485 communication option.
While the parameter names appear, and keys are
pressed together,the program will return to the menu display.
Entering from programming mode to run mode:
If no key is pressed within 20 seconds during programming mode data is stored automatically and the run mode is entered.After pressing button and then passed
to the program menu by pressing key is pressed in combination with keys and the information is recorded.
S.Cod = Access code for safety
menu.
This parameter should be 2041.
Security code is 0; key is pressed
continuously for 5 secoonds,dEfP
message is displayed and return to
U.c.Sc. = U.cnF. menu protection
level parameter.
nonE = No menu is seen
P.yEs = Modification feasible
P. no = Only traceable
o.tyP... = Output type selection parameter
0-10 = 0-10V output usable
4-20 = 4-20mA output usable
0-20 = 0-20mA output usable
See NOTE 1 for programming
o.C.sc. = o.Cnf. Menu protection
level parameter.
nonE = No menu is seen
P.yEs = Modification feasible
P. no = Only traceable
Pno = Menu visible.
d.Pnt.
L.ScL..
H.ScL.
Hi.Li.
d.ADr.
Lo.Li.
bAud
U.CnF..
U.CnF..
o.CnF.
o.cnF.
SECu.
SEcu.
S.Cod.
U.C.sc.
p.YES
Off
DsaB
DsaB
30
30
1
0-10
0
0
9999
0
1
1500
9.60
p.YES
o.typ..
o.C.sc.
pon.C.
o.E.ty.
o.d.ty..
r.ti.
d.ti.
P.i.rt.
SET
SET
SET
Programming Mode
Running Mode
baud = Baud rate for the RS485 connection.
Adjustable;off,2400,4800,9600,19200 and 38400.
This parameter is active device with RS485 communication
option.
+
+
+
Return to
the menu.
Return to
the menu
Return to
the menu
Default
Parameters
Default
parameters
Default
parameters
key is pressed whole in the run mode,preset setup mode is entered and PrSt. message is displayed. Message appears when the or button is pressed, the preset value starts to flash. By using
keys ,preset value can be adjusted.Preset value can be adjusted by using external buttons as well.External buttons become disable in programming mode.If the device is also controlled by a potentiometer,
adjustable preset value appears as above.
If o.Et.y and o.d.t.Y parameters are adjusted to any value expect dSAb parameter,
output can be controlled with and buttons.
Preset
value
Active
output value
or
1000
1001
1002
1002
1003
S
ET
S
ET
1000
PrSt.
If no key is pressed
for 3 seconds
OUTPUT DIAGRAM
+
+
ofF= When first energized, output is the voltage or current that lower limit value is indicated.
Attention: If this parameter is selected, the set value that was adjusted before is seen when set button is
pressed at first. In addition,if increasing or decreasing that value is wanted the set value is equalized to
lower limit value and then adjustment can be done.
On= When first energized, output is the voltage or current hat the set value is indicated.
S.Str.= When first energized, output is increased slowly from the voltage or current that lower limit value is
indicated to the voltage or current that set value is indicated during r.ti.
See NOTE 1 for programming.
For adjusting a selected parameter first press and hold key. Then, by using
keys, adjustment can be made.
Parameter Adjustment Method
NOTE 1
If increment key is pressed and held 0.6 seconds, the value of the selected parameter
changes rapidly. If waited enough, the value increases 100 at each step. After 1 second following
the release of the key, initial condition is returned. The same procedure is valid for the decrement
key.
S
ET
6
5 6
Lo.Li.
SET SET
SET
SET
P.on.C.
o.d.ti.
E.d.ti.
o.E.ty.
E.E.ty.
Out
Out
Out
Lo.li.
PRESET
Lo.li.
Lo.li.
PRESET
PRESET
UP input
preset increased
preset decremented
H
H
L
L
DOWN input
Power
0V
On
Can not control with
buttons.
off
Dsab.
Dsab.
Dsab.
Dsab.
On
Enb.
Enb.
Enb.
Enb.
When key
is pressed
r.ti.
r.ti.
S.str.
S.ofF
S.ofF
S.on
S.on
r.ti.
d.ti.
d.ti.
E.E.ty. = Returning method of the output to preset value with the external "Up" input.
o.E.tY. is set like the output parameter.
E.d.ty. = Returning method of the output to
preset value with the external "Down" input.
o.d.tY. is set like the output parameter.
DsaB
DsaB
E.E.ty..
E.d.ty..
When key
is pressed
When key
is pressed
When key
is pressed
3. / 4
EDP2041-EN-15092021