Instructions

In the current measurement mode input impedance is 5W. Therefore, in the current measurement mode, any voltage input
should not be connected to the input terminals. Otherwise, the device will be broken down. To change the input type from
voltage to a current measurement mode while the device is operating, first, leave out the voltage inputs. Then, change
input type to one of the current measurement modes.
EI141 must not be used in location where measurement category is II, III or IV.
* 35x77mm sized.
* 4 digits display.
* Easy to use by front panel keypad.
* Display scale can be adjusted between -1999 and 4000.
* Decimal point can be adjusted between 1. ile 3. digits.
* Measurement unit can be displayed.
* Selectable four different standard input types (0-20mA, 4-20mA, 0-1V, 0-10V)
* User can calibrate the device according to his/her own specified input type.
* Sampling time can be adjusted in four steps.
* Maximum and minimum measurement values are registered.
* The maximum or the minimum values can be hold on the display.
* Current and voltage calibration can be made..
* Parameter access protection on 3 levels.
* Easy connection by removable screw terminal.
Input type
0-1V DC voltage
0-10V DC voltage
0-20mA DC current
4-20mA DC current
Input empedance
Approx. 11kW (terminal voltage limits: min. = -2V, max. = 30V)
Approx. (terminal voltage limits: min. = -2V, max. = 30V) 11kW
Approx. 5W (applicable terminal voltage is max. 50mA.)
Approx. (applicable terminal voltage is max. 50mA.) 5W
ENDA EI141 PROGRAMMABLE INDICATOR
Thank you for choosing ENDA EI141 INDICATOR.
Read this document carefully before using this device. The guarantee will be expired by
damaging of the device if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
Ambient/storage temperature
Max. relative humidity
0 ... +50 °C/-25 ... +70°C (with no icing)
Rated pollution degree
TECHNICAL SPECIFICATIONS
80% up to 31 decreasing linearly 50% at 40 . °C °C
According to EN 60529 Front panel : IP65
Rare panel : IP20
Do not use the device in locations subject to corrosive and flammable gases.
Supply
230VAC +10%/-20%, 50/60Hz, 24VAC±10%,50/60Hz or 24Vac/dc (9-30Vdc or 7-24Vac)
Power consumption
Max. 7VA
2.5mm² screw-terminal connections
Wiring
Date retention
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for the EMC standard)
EEPROM (Min. 10 years)
EN 61010-1: 2001 (pollution degree 2, overvoltage category II, measurement category I)
ELECTRICAL CHARACTERISTICS
HOUSING
Housing type
Suitable for flush-panel mounting according to DIN 43 700.
Dimensions
W77xH35xD71mm
Weight
Approx. 250g (after packing)
Enclosure material
Self extinguishing plastics
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
0V
±0,5% (of full scale)
0V
±0,5% (of full scale)
0mA
±0,5% (of full scale)
0mA
±0,5% (of full scale)
1.1V
14V
25mA
25mA
Min.
Max.
Measurement range
Measurement accuracy
english
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
up to date: 03072010, modification reserved and can be change any time previous notice !
1./3 EI141-E
SETSET
EI141
ENDA
PROGRAMMABLE INDICATOR
Order Code : EI141-
1
1 - Supply Voltage
230VAC...230V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC

Summary of content (3 pages)