Datasheet
4 7 LEDdigits segment red display
( 4 ),( 5 ),( 6 ),( 7 ) Key pad
( 3 ) Digital display
5) Shows minimum measured value Run mode
Decreases value or adjusts parameter. (Programlama modu)
. ( )
6)
. ( )
Shows alarm set value.
Menu selection key Programming mode
( )Run mode
7) Shows out set value. ( )
. (Program mod )
Run mode
Parameter adjustment key ming e
14.2mm
Mikro switch
Character height
3mm LEDbright red
Alarm LEDOut and( 1 ),( 2 )
TERMS
3)
. ( mod )
. ( )
Shows measurement value, measurement unit and maximum and
minimum measured values Run e
Shows name, value and unit of parameters Programming mode
4)
( )
Shows maximum measured value
Programming mode
. ( )Run mode
Increases value or adjusts parameter.
1) .Shows out status
2) .Shows alarm status
CONNECTION DIAGRAM
ENDA EI7412isintendedforinstallationincontrolpanels.Makesurethatthedeviceisusedonlyforintendedpurpose.
Duringaninstallation,allofthecablesthatareconnectedtothedevicemustbefreeofenergy. Thedevice
mustbeprotectedagainstinadmissiblehumidity,vibrations,severesoilingandmakesurethattheoperationtemperatureisnotexceeded. All
inputandoutputlinesthatarenotconnectedtothesupplynetworkmustbelaidoutasshieldedandtwistedcables. Thesecablesshouldnotbe
closetothepowercablesorcomponents.
Theshieldingmustbe
groundedontheinstrumentside.
Theinstallationandelectricalconnectionsmustbecarriedonbyaqualifiedstaffandmustbe
accordingtotherelevantlocallyapplicableregulations.
1)MainssupplycordsshallmeettherequirementsofIEC60227orIEC60245.
2)Inaccordancewiththesafetyregulations,thepowersupplyswitchshallbringtheidentificationoftherelevantinstrumentandit
shouldbeeasilyaccessiblebytheoperator.
Note:
8
7
184-253V AC
50/60Hz 7VA
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Neutral
Line
SUPPLY :
NOTE :
Fuse should
be connected
Holdingscrew
0.4-0.5Nm
Equipmentis protected throughout
by DOUBLEINSULATION.
PROGRAMMABLE INDICATOR
ENDA
EI 7412
OSET
SET
MAX
ASET
OUT
ALR
MIN
Panel cut-out
75mm
84mm
68mm
+0.7
68mm
+0.7
Depth
97mm
2
2
Note1)Whilepanelmounting,additionaldistancerequired
forconnectioncablesshouldbeconsidered.
2)Panelthicknessshouldbemaximum10mm.
3)Ifthereisno90mmfreespaceatbacksideofthedevice,
itwouldbedifficulttoremoveitfromthepanel.
Pushtheflush-mounting
clampindirection as
showninthefigureleft.
Then,pullouttheclampin
direction
-
1
-
2.
Forremovingmountingclamps:
Connection
cables
Rubber packing
Flush mounting
clamp
Panel
1
1
DIMENSIONS
72mm
78mm
PROGRAMMABLE INDICATOR
ENDA
EI 7412
SET
MAX
ASET
OUT
ALR
OSET
MIN
INPUT
+
GND
230V AC +10% -20%
50/60Hz 7VA
7
8
9
10
SN: XXXXXXXXX
ENDA
INDUSTRIAL ELECTRONICS
EI7412-230VAC-AS24
INDICATOR
ALARM
AC 250V 8A
RESISTIVE LOAD
1
2
AUXILIARY
SUPPLY OUT
24V 50mA
+
GND
3
4
OUT
AC 250V 8A
RESISTIVE LOAD
5
6
INPUT
+
GND
230V AC +10% -20%
50/60Hz 7VA
7
8
9
10
SN: XXXXXXXXX
ENDA
INDUSTRIAL ELECTRONICS
EI7412-230VAC-AS12
INDICATOR
ALARM
AC 250V 8A
RESISTIVE LOAD
1
2
AUXILIARY
SUPPLY OUT
12V 50mA
+
GND
3
4
OUT
AC 250V 8A
RESISTIVE LOAD
5
6
INPUT
+
GND
7
8
9
10
SN: XXXXXXXXX
ENDA
INDUSTRIAL ELECTRONICS
EI7412-24VAC-AS05
INDICATOR
ALARM
AC 250V 8A
RESISTIVE LOAD
1
2
AUXILIARY
SUPPLY OUT
24V 50mA
+
GND
3
4
OUT
AC 250V 8A
RESISTIVE LOAD
5
6
24V AC ±10%
50/60Hz 7VA
INPUT
+
GND
7
8
9
10
SN: XXXXXXXXX
ENDA
INDUSTRIAL ELECTRONICS
EI7412-24VAC
INDICATOR
ALARM
AC 250V 8A
RESISTIVE LOAD
1
2
3
4
OUT
AC 250V 8A
RESISTIVE LOAD
5
6
24V AC ±10%
50/60Hz 7VA
INPUT
+
GND
9
10
SN: XXXXXXXXX
ENDA
INDUSTRIAL ELECTRONICS
EI7412-SM
INDICATOR
ALARM
AC 250V 8A
RESISTIVE LOAD
1
2
3
4
OUT
AC 250V 8A
RESISTIVE LOAD
5
6
9-30V DC / 7-24V AC
±10% 7VA
7
8
INPUT
+
9
ALARM
AC 250V 8A
RESISTIVE LOAD
1
2
9-30V DC / 7-24V AC
±10% 7VA
7
8
AUXILIARY
SUPPLY OUT
8V 50mA
+
3
GND
10
SN: XXXXXXXXX
ENDA
INDUSTRIAL ELECTRONICS
EI7412-SM-AS08
INDICATOR
OUT
AC 250V 8A
RESISTIVE LOAD
5
6
GND
4
4 I7 1 E./4E 4 2-