User manual

OUTPUTS
Alarm output
Relay: 250V AC, 8A (for resistive load), NO+NC
Mechanical 30.000.000 ; Electrical 100.000 operation.
Life expectancy for relay
0 ... +50°C/-25 ... 70°C
HOUSING
Housing type
Suitable for flush-panel mounting. (According to DIN 43 700)
Dimensions
W77xH35xD71mm
Weight
Enclosure material
Self extinguishing plastics.
ENDA EPV241A AC/DC VOLTMETER
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
Approx. 350g (after packing)
SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.
Yukarı Dudullu Barbaros Cad. Kutup Sok. No:20 34775 - ÜMRANİYE/İSTANBUL/TÜRKİYE
Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01
url : www.enda.com.tr
* 77 x 35mm sized.
* 3 digits display.
*
* Easy to configure with front panel keypad.
* Multifunctional alarm output (NO+NC) for upper and lower
limits.
* Communication feature over isolated RS485, using ModBus
RTU protocol. (Functional).
* Measuring type can be selected as AC, DC or true RMS.
* CE marked according to Europan Norms.
Values between -100V and 100 V can be indicated with one
decimal point.
* For maximum 50V AC/DC measurements;10 times the
sensitivity of the measurement values between -50V and +50V
with two decimal places to show.
Supply
230V AC +10% -20%, 50/60Hz or 24V AC 10% , 50/60Hz or optional 9-30V DC / 7-24V AC 10% SMPS± ±
Power consumption
2.5mm² screw-terminal connections
Wiring
Scale
Sensitivity
ELECTRICAL CHARACTERISTICS
If C.InP; 500 is selected, it is 0V...500V or If C.ınP ;50 is selected, it is 0....50V
If C.InP ;500 is selected, it is -500V DC....500V DC or If C.InP;50 is selected, it is -50V DC....50V DC
0,01V (If C.InP;50 is selected )
Max. 5VA
AC and RMS:
DC :
EPV241A-E-02-R-201307
1/5
±
Accuracy
EMC
Safety requirements
EN 61326-1: 2006
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
1%
AC
RMS
DC
±
1%
1%
(Full scale) (For square wave form 2%)±
(Full scale)
Input Impedance
870kΩ
Frequency Range
Input Range
-500V...500V (If CINP 500 is selected, device breaks down at more than ±1250 DC voltages.)
-50V....50V (If CInp 50 is selected, device breaks down at more than ±125 DC voltages.)
±
(Full scale) (For square wave form 2%)
±
DC , 10Hz - 200Hz (For square wave form 10Hz-70Hz)
Thank you for choosing ENDA EPV241 AC/DC voltmeter.
Read this document carefully before using this device. The guarantee will be expired by
device damages if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
Technical Specifications
.Do not use the device in locations subject to corrosive and flammable gases
ENVIRONMENTAL CONDITIONS
Ambient/stroge temperature
Max. Relative humidity
Rated pollution degree
Height
80 Relative humidity for temperatures up to 31 % °C,decreasing linearly to 50% at 40°C.
According to EN 60529 Front panel : IP65 , Rear panel : IP20
Max. 2000m
0,1V (If CINP;500 is selected and higher than -100V or lower than 100V for input values)
1V (If CINP;500 is selected and lower than -100V or higher than 100V for input values)
1-Output
R......Relay
None...No relay
2-Supply Voltage
230VAC...230V AC RSI..... Insulated ModBus (optional)
110VAC...110V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
3-ModBus
SETSET
EPV 241A
ENDA
OUT AC DC ACDC
V
Order Code : EPV241A- - -
2
3
1