Cleaning Instructions

25Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen • Series: 220000-450000
For assistance call: 1.800.762.1142
Step 29 – 30
29. Check burner connections:
1. Make sure the regulator valve and hose connections are securely fastened to the
burner and the tank.
2. If your unit was assembled for you, visually check the connection between the
venturi tube and orifice. Make sure the venturi tube fits over the orifice.
W WARNING: Failure to inspect this connection or follow these instructions
could cause a fire or an explosion which can cause death, serious bodily
injury, or damage to property.
3. If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142
for assistance.
30. Tank/Gas Line Connection
1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with
three parts water.
2. Make sure control knob is in “OFF” position. (Figure 3)
3. Turn LP gas tank valve to “OPEN”.
4. Spoon leak check solution at all “X” locations. (Figures 1 and 2)
a. If any bubbles appear turn LP gas tank valve to “CLOSED”, reconnect and re-
test.
b. If you continue to see bubbles after several attempts, turn LP gas tank valve
to “CLOSED”, disconnect LP gas tank and contact 1.800.762.1142 for
assistance.
c. If no bubbles appear after one minute turn LP gas tank valve to “CLOSED”,
wipe away solution and proceed.
Figure 1
X
X
Figure 2
X
X
X
X
X
Figure 3
PILOT / VEILLEUSE
push in / pressez et maintenez
LOW /
BAS
HIGH /
HAUT
OFF /
ARRÊT