Instructions / Assembly

LP Gas Outdoor Fireplace
Model No. GAD16677SP
6
Installing LP Gas Tank
To operate, you will need one precision-filled standard
grill LP gas tank with external valve threads (Figure 1).
W CAUTION: LP gas tank must be properly
disconnected and removed prior to
moving this outdoor fireplace.
Inserting LP Gas Tank
W WARNING: Make sure LP gas tank valve
is closed.
W WARNING: The LP gas tank shall be
placed 72 inches minimum away from
appliance. Placing LP gas tank too
close to the appliance could cause
tipping hazard.
1. Loosen LP gas tank retainer bolt by turning
counter-clockwise (Figure 4)
2. Place precision-filled LP gas tank upright into hole
in LP gas tank stand so the tank valve is facing the
gas line connection (Figure 2).
3. Secure tank by turning LP gas tank retainer bolt
clockwise until tight (Figure 4).
Connecting LP Gas Tank (Figure 5)
1. Make sure the control knob is in the OFF”
position (Figure 9).
2. Before connecting, be sure there is no debris
caught in the head of the LP gas tank, head of
the regulator valve or in the head of the burner or
burner ports.
3. Connect regulator/hose assembly to tank by
turning knob clockwise until it stops. Make sure
there’s at least 72 inches (183 cm) of space
between the tank and the appliance.
4. Perform leak check per “Checking for Leaks”
section.
Disconnecting LP Gas Tank (Figure 6)
1. Make sure the control knob is in the OFF”
position (Figure 9).
2. Before disconnecting, make sure the LP gas tank
valve is “CLOSED.”
3. Disconnect regulator/hose assembly from LP gas
tank by turning knob counterclockwise until it is
loose.
W CAUTION: LP gas tank must be properly
disconnected and removed prior to
moving this grill.
4. Place the protective cap cover on the LP tank and
store the tank outdoors in a well ventilated area
out of direct sunlight.
Checking for Leaks
W WARNING: Before using this outdoor
fireplace, make sure you have
read, understand and are following
all information provided in the
“Important Safeguards” section.
Failure to follow those instructions
can cause death, serious injury or
property damage.
Burner Connections
1. Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank.
2. Visually check the connection between the
burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the
orifice.
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4. Please refer to diagram for proper installation
(Figures 7 and 8).
5. If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1.800.762.1142 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak detection solution by
mixing one part liquid dishwashing soap with
three parts water.
2. Make sure control knobs are in the
OFF”
position (Figure 9).
3. Connect LP gas tank per “Installing LP Gas
Tank” section.
4. Turn LP gas tank valve to “OPEN.”
5. Spoon several drops of solution, or use a squirt
bottle, at all “X” locations (Figures 7 and 8).
a. If any bubbles appear, turn LP gas tank valve
to “CLOSED, reconnect and re-test.
b. If you continue to see bubbles after
several attempts, turn LP gas tank valve to
“CLOSED” and disconnect LP gas tank, per
“Disconnecting LP Gas Tank” section. Contact
1.800.762.1142 for assistance.
c. If no bubbles appear after one minute, turn
LP gas tank valve to “CLOSED, wipe away
solution and proceed.
Lighting
W WARNING: NEVER light the burner
with the cover on the outdoor
fireplace.
W CAUTION: Keep outdoor gas
appliance area clear and free from
combustible materials, gasoline and
other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of
combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
1. Make sure all labels, packaging and protective films have been removed from the outdoor
fireplace.
2. Check for obstructions of airflow to the burner. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3. Control knob must be in the
OFF” position (Figure 9).
4. Clear small area of lava rocks away from the igniter cover (Figure 10).
5. Connect LP gas tank per “Installing LP Gas Tank” section.
6. Turn LP gas tank valve to “OPEN.”
7. Push the control knob in and slowly turn it to
(HIGH). Continue to hold the control knob in
to light.
8. After 20 seconds, release and turn control knob counterclockwise to adjust ame to desired
height.
9. After three attempts, if ignition does not occur, turn the burner control knob to
OFF.”
10. If ignition does not occur in 5 seconds, turn burner control knob to OFF, wait
5 minutes, fan with a newspaper or magazine, and repeat lighting procedure.
Operating Instructions
Figure 7
LP Gas Valve
with Orifice
LP Gas
Connection
Figure 8
X
X
X
X
X
Figure 9
OFF / ARRÊT
Figure 10
Figure 11
15.7 in – 23.6 in
40 – 60 cm
Figure 1
20 lb
9 Kg
17.9 in. / 45.5 cm
12.2 in. / 31 cm
Figure 2
Figure 3
Figure 4a
Figure 4b
Figure 4c
Figure 5
Figure 6