Troubleshooting - Lower Burner
Problem Possible Cause Prevention/Cure
Pilot won’t light
LP gas tank valve is closed
Make sure regulator is securely attached to the LP gas tank per “Installing LP Gas Tank,”
then turn LP gas tank valve to “OPEN.”
LP gas tank is low or empty Exchange, refill or replace LP gas tank
LP gas leak
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Battery needs to be changed Replace the “AA battery (follow assembly step for inserting battery)
Igniter fails
Light the heater manually with a match, per the “Lighting Instructions.” If heater lights with
a match, replace igniter - contact Customer Care at 800.762.1142.
Blockage in pilot or orifice
Clean the pilot assembly: Download and follow the correct cleaning instructions from
BlueRhino.com.
Air in gas line
1. Open gas line and bleed it (pressing control knob in) for not more than 1 - 2 minutes or
until you smell gas
2. Turn control knob to
OFF”
3. Wait at least 5 minutes for gas to dissipate
4. Light per “Lighting” section.
Burner won’t light
Note: Burner operates at reduced
efficiency below 40ºF (5ºC).
Control knob is NOT in an ON position Review “Lighting” section and try again
Control knob IS in an ON position Review “Lighting” section and try again
LP gas tank is low or empty Exchange, refill or replace LP gas tank
LP gas leak
1. Turn LP gas tank valve to “CLOSED”
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Blockage in orifice Clear blockage: Download and follow the correct cleaning instructions from BlueRhino.com
Connection between gas valve and burner assembly is
loose
1. Turn off heater per “Turning Off section.
2. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
3. Tighten connection.
4. Perform leak check per “Checking for Leaks” instructions.
5. Light per “Lighting” section.
Thermocouple is not operating correctly
1. Disconnect LP Gas tank per “Disconnect LP Gas Tank” section.
2. Clean area around thermocouple.
3. Connect LP gas tank per “Connect LP Gas Tank” section.
4. Relight per “Lighting” section.
5. If the outdoor fire table is still not working, please contact Customer Care at
800.762.1142 for additional assistance.
Air in gas line
1. Open gas line and bleed it (pressing control knob in) for not more than 1 - 2 minutes or
until you smell gas.
2. Wait 5 minutes for gas to clear
3. Follow “Checking for Leaks” section
Pilot won’t stay lit
Note: Heater operates at reduced
efficiency below 40ºF (5ºC).
Dirt built up around pilot
Clean the pilot assembly: Download and follow the correct cleaning instructions from
BlueRhino.com.
Connection between gas valve and pilot assembly is
loose
1. Turn off heater per “Turning Off section.
2. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
3. Tighten connection.
4. Perform leak check per “Checking for Leaks” section.
5. Light per “Lighting” section.
Air in gas line
Open gas line and bleed it (pressing control knob in) for not more than 1 - 2 minutes or until
you smell gas.
Thermocouple is not operating correctly
1. Disconnect LP Gas tank per “Disconnect LP Gas Tank” section.
2. Clean area around thermocouple.
3. Connect LP gas tank per “Connect LP Gas Tank” section.
4. Relight per “Lighting” section.
5. If the outdoor fire table is still not working, please contact Customer Care at
800.762.1142 for additional assistance.
Burner won’t stay lit
Connection between gas valve and burner assembly is
loose
Tighten connection and perform leak check.
Thermocouple is not operating correctly
1. Disconnect LP Gas tank per “Disconnect LP Gas Tank” section.
2. Clean area around thermocouple.
3. Connect LP gas tank per “Connect LP Gas Tank” section.
4. Relight per “Lighting” section.
5. If the outdoor fire table is still not working, please contact Customer Care at
800.762.1142 for additional assistance.
Blockage in burner
1. Turn off heater per “Turning Off instructions.
2. Remove blockage and clean burner inside and outside:
Download and follow the correct cleaning instructions from BlueRhino.com
3. If the heater is still not working, replacement part(s) may be needed - contact Customer
Care at 800.762.1142
Burner flame is low
Note: Heater operates at reduced
efficiency below 40ºF (5ºC).
LP gas tank is low or empty Exchange, refill or replace LP gas tank
Outdoor temperature is less than 40ºF and tank is less
than 1/4 full
1. Turn off heater per “Turning Off section.
2. Connect a full LP Gas Tank per “Connecting LP Gas Tank” section.
Supply hose is bent or kinked
1. Turn off heater per “Turning Off section.
2. Straighten hose. If cracked obtain a new hose from the manufacturer - contact
Customer Care at 800.762.1142
Emitter glows uneven
Note: Bottom 1 in of emitter normally
does NOT glow.
LP gas tank is low or empty Exchange, refill or replace LP gas tank
Base is not on a level surface Place heater on a level surface
Blockage in burner
1. Turn off heater per “Turning Off section.
2. When cool, remove blockage and clean burner inside and outside.
3. Download and follow the correct cleaning instructions from BlueRhino.com.
Thick black smoke Blockage in burner
1. Turn off heater per “Turning Off section.
2. When cool, remove blockage and clean burner inside and outside.
3. Download and follow the correct cleaning instructions from BlueRhino.com.
For assistance, please visit us at BlueRhino.com or call 1.800.762.1142.