Owner's Manual

Need help? 1.800.762.1142
Do not return to place of purchase.
Replacement Parts
1.800.762.1142
7
6. Turn LP gas tank valve to “OPEN.”
7. Push and turn control knob to (HIGH). Continue to hold the control knob in to light.
8. After the fire table lights, continue to hold the control knob in for 20 seconds to heat the
thermocouple, a safety device that stops the gas flow when a firepit is not lit. Holding the
knob in for 20 seconds warms it up so the gas flow will continue.
9. After 20 seconds, release and turn control knob counterclockwise to adjust flame to
desired height.
10. After three attempts, if ignition does not occur, turn the burner control knob to OFF.”
11. Wait 5 minutes, fan with a newspaper or magazine, and repeat lighting procedure.
12. If igniter does not light burner:
a. Wearing heat-resistant gloves, position a lit long match or lit long butane lighter near
the pilot housing (Figure 4).
b. Push and turn control knob to
(HIGH).
c. Remove match/lighter once burner is lit.
W CAUTION: After lighting - using a fireplace tool and heat-resistant
gloves, carefully move the glass rocks back to their proper position,
being careful to avoid the flame.
13. After lighting, observe the burner flame. Make sure all burner ports are lit and flame height
matches illustration (Figure 5).
W CAUTION: If ignition does not occur in 5 seconds, turn control knob
to “
OFF, wait 5 minutes, fan with a newspaper or magazine, and
repeat lighting procedure.
Turning Off
1. Turn LP gas tank valve to “CLOSED.”
2. Turn control knob to the
OFF” position.
Note: A “poof” sound is normal as the last of the LP gas is burned.
3. Disconnect LP gas tank per “Disconnecting LP Gas Tank” section.
Lower Burner
W WARNING: NEVER light the burner with the cover on the outdoor
fireplace.
W WARNING: Always use this outdoor fire table on a hard, level, non-
combustible surface such as concrete, rock or stone. An asphalt or
blacktop surface may not be acceptable for this purpose.
W CAUTION: Keep outdoor gas appliance area clear and free from
combustible materials, gasoline and other flammable vapors and
liquids.
W CAUTION: Do NOT obstruct the flow of combustion and ventilation air.
W CAUTION: Check and clean burner/venturi tubes for insects and insect
nests. A clogged tube can lead to a fire.
W CAUTION: If relighting a hot heater, always wait at least 5 minutes
before relighting.
Note: The upper and lower burners are independent.
Note: This outdoor fireplace is equipped with a pilot light that allows for safer startups and
shutdowns. Pilot must be lit before main burner can be started.
Lighting
1. Make sure all labels, packaging and protective
films have been removed from the outdoor
fireplace.
2. Check for obstructions of airflow to the burner.
Spiders, insects and webs can clog the burner/
venturi tube. A clogged burner tube can lead to
a fire.
3. Make sure the control knobs are in the
OFF”
position (Figure 3).
4. Connect LP gas tank per “Installing LP Gas
Tank” section.
5. Turn LP gas tank valve to “OPEN.”
6. Push and turn control knob to (HIGH). Continue
to hold the control knob in to light.
7. After the fire table lights, continue to hold the
control knob in for 20 seconds to heat the
thermocouple, a safety device that stops the gas
flow when a firepit is not lit. Holding the knob in
for 20 seconds warms it up so the gas flow will
continue.
8. After 20 seconds, release and turn control knob
counterclockwise to adjust heat to desired
temperature.
Checking for Leaks
W WARNING: Before using this outdoor
fireplace, make sure you have
read, understand and are following
all information provided in the
“Important Safeguards” section.
Failure to follow those instructions
can cause death, serious injury or
property damage.
Burner Connections
1. Make sure the regulator hose and valve
connections are securely fastened to the burner
and the tank.
2. Visually check the connection between the
burner/venturi tube and orifice.
3. Make sure the burner/venturi tube fits over the
orifice.
W WARNING: Failure to inspect
this connection or follow these
instructions could cause a fire or an
explosion which can cause death,
serious bodily injury or damage to
property.
4. Please refer to diagram for proper installation
(Figures 1 and 2).
5. If the burner/venturi tube does not rest flush
to the orifice, as shown, please contact
1.800.762.1142 for assistance.
Tank/Gas Line Connection
1. Make 2-3 oz. of leak detection solution by
mixing one part liquid dishwashing soap with
three parts water.
2. Make sure control knobs are in the
OFF”
position (Figure 3).
3. Connect LP gas tank per “Installing LP Gas
Tank” section.
4. Turn LP gas tank valve to “OPEN.”
5. Spoon several drops of solution, or use a squirt
bottle, at all “X” locations (Figures 1 and 2).
a. If any bubbles appear, turn LP gas tank valve
to “CLOSED,” reconnect and re-test.
b. If you continue to see bubbles after
several attempts, turn LP gas tank valve to
“CLOSED” and disconnect LP gas tank, per
“Disconnecting LP Gas Tank” section. Contact
1.800.762.1142 for assistance.
c. If no bubbles appear after one minute, turn
LP gas tank valve to “CLOSED,” wipe away
solution and proceed.
Upper Burner
W WARNING: NEVER light the burner
with the cover on the outdoor
fireplace.
W CAUTION: Keep outdoor gas
appliance area clear and free from
combustible materials, gasoline and
other flammable vapors and liquids.
W CAUTION: Do NOT obstruct the flow of
combustion and ventilation air.
W CAUTION: Check and clean burner/
venturi tubes for insects and insect
nests. A clogged tube can lead to a
fire.
Note: The upper and lower burners are independent.
Note: This outdoor fireplace is equipped with a pilot light that allows for safer startups and
shutdowns. Pilot must be lit before main burner can be started.
Lighting
1. Make sure all labels, packaging and protective films have been removed from the outdoor
fireplace.
2. Check for obstructions of airflow to the burner. Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube can lead to a fire.
3. Make sure the control knobs are in the
OFF” position (Figure 3).
4. Clear small area of glass rocks away from the igniter cover (Figure 4).
5. Connect LP gas tank per “Installing LP Gas Tank” section.
Figure 1
LP Gas
Connection
LP Gas Valve
with Orifice
Figure 2
X
X
X
X
X
Figure 3
OFF / ARRÊT
Figure 4
K
F
AA
Figure 5
11.8 in. – 19.7 in.
30 – 50 cm
Operating Instructions
Figure 6
K
F
AA
Figure 7
K
F
AA
Figure 8
Burner
Flame
Slight
Yellow
Slight
Blue
Dark
Blue