Product Info
Table Of Contents
- Table of contents
- Wichtige Hinweise zum Dokument
- Function and system design
- Input
- Output
- Power supply
- Performance characteristics
- Installation
- Environment
- Process
- Mechanical construction
- Operability
- Certificates an approvals
- CE mark
- RoHS
- RCM-Tick marking
- Ex approval
- Dual seal according to ANSI/ISA 12.27.01
- Functional safety
- WHG
- Sanitary compatibility
- NACE MR 0175 / ISO 15156
- NACE MR 0103
- Pressure equipment with allowable pressure ≤ 200 bar (2
- Marine certificate
- Radio standard EN302729
- Radio standard EN 302372
- FCC
- Industry Canada
- Japanese radio approval
- CRN approval
- Track record
- Test, Certificate
- Hard-copy product documentation
- Other standards and guidelines
- Ordering information
- Application Packages
- Accessories
- Documentation
DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFTDRAFT DRAFT DRAFT
Micropilot FMR51, FMR52
104 V. 10, Rev. 3, 1-10-2019 Endress+Hauser
Customized parametrization
If the option IJ "Customized parametrization HART", IK "Customized parametrization PA" or IL
"Customized parametrization FF" has been selected in feature 570 "Service", customer specific
presettings can be selected for the following parameters:
Parameter Communication Selection list / range of
values
Setup → Distance unit • HART
• PA
• FF
• in
• ft
• mm
• m
Setup → Empty calibration • HART
• PA
• FF
max. 70 m (230 ft)
Setup → Full calibration • HART
• PA
• FF
max. < 70 m (230 ft)
Setup → Adv. Setup → Current output 1/2 → Damping HART 0 to 999.9 s
Setup → Adv. Setup → Current output 1/2 → Failure mode HART • Min
• Max
• Last valid value
Setup → Adv. Setup → Current output 1/2 → Burst mode HART • Off
• On
Tagging (TAG)
Ordering feature 895: Marking
Option Z1: Tagging (TAG), see additional spec.
Position of the measuring
point marking
To be selected in the additional specifications:
• Tag plate Stainless Steel
• Self-adhesive paper label
• Supplied label/plate
• RFID TAG
• RFID TAG + Tag plate Stainless Steel
• RFID TAG + Self-adhesive paper label
• RFID TAG + Supplied label/plate
Definition of the measuring
point designation
To be defined in the additional specifications:
3 lines containing up to 18 characters each
The measuring point designation appears on the selected label and/or the
RFID TAG.
Designation in the Electronic
Name Plate (ENP)
The first 32 characters of the measuring point designation
Designation on the display
module
The first 12 characters of the measuring point designation
Services
The following services can be selected via the product structure in the Product Configurator
9)
:
• PWIS free (PWIS: paint wetting impairment substances)
• Customized parametrization HART → 104
• Customized parametrization PA→ 104
• Customized parametrization FF → 104
• Without tooling DVD (FieldCare)
9) Feature 570 of the product structure