Product Info
Table Of Contents
- Table of contents
- Wichtige Hinweise zum Dokument
- Function and system design
- Input
- Output
- Power supply
- Performance characteristics
- Installation
- Environment
- Process
- Mechanical construction
- Operability
- Certificates an approvals
- CE mark
- RoHS
- RCM-Tick marking
- Ex approval
- Dual seal according to ANSI/ISA 12.27.01
- Functional safety
- WHG
- Sanitary compatibility
- NACE MR 0175 / ISO 15156
- NACE MR 0103
- Pressure equipment with allowable pressure ≤ 200 bar (2
- Marine certificate
- Radio standard EN302729
- Radio standard EN 302372
- FCC
- Industry Canada
- Japanese radio approval
- CRN approval
- Track record
- Test, Certificate
- Hard-copy product documentation
- Other standards and guidelines
- Ordering information
- Application Packages
- Accessories
- Documentation
DRAFT DRAFT DRAFT DRAFT DRAFT DRAFT DRAFTDRAFT DRAFT DRAFT
Micropilot FMR51, FMR52
62 V. 10, Rev. 3, 1-10-2019 Endress+Hauser
FMR52
Antenna: Horn 80mm/2"
Housing: GT19 (Plastics PBT)
Temperature unit: °C (°F)
A0019351
Power Supply; Output (Pos. 2
of the product structure)
P1 P2 P3 P4 P5 P6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A -40
(-40)
80
(176)
80
(176)
80
(176)
200
(392)
36
(97)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
B
Switch output not used
-40
(-40)
76
(169)
76
(169)
76
(169)
200
(392)
36
(97)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
B
Switch output used
-40
(-40)
60
(140)
60
(140)
60
(140)
200
(392)
27
(81)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
C
Channel 2 not used
-40
(-40)
82
(180)
82
(180)
82
(180)
200
(392)
36
(97)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
C
Channel 2 used
-40
(-40)
74
(165)
74
(165)
74
(165)
200
(392)
36
(97)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
E, G
Switch output not used
-40
(-40)
79
(174)
79
(174)
79
(174)
200
(392)
36
(97)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
E, G
Switch output used
-40
(-40)
63
(145)
63
(145)
63
(145)
200
(392)
30
(86)
200
(392)
-40
(-40)
-40
(-40)
-40
(-40)
- -
FMR52
Antenna: Horn 80mm/2"
Housing: GT20 (Alu, coated)
Temperature unit: °C (°F)
A0019351
Power Supply; Output (Pos. 2
of the product structure)
P1 P2 P3 P4 P5 P6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
A -196
(-321)
81
(178)
81
(178)
81
(178)
200
(392)
61
(142)
200
(392)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-8
(+18)
B
Switch output not used
-196
(-321)
82
(180)
82
(180)
82
(180)
200
(392)
62
(144)
200
(392)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-8
(+18)
B
Switch output used
-196
(-321)
77
(171)
77
(171)
77
(171)
200
(392)
56
(133)
200
(392)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-8
(+18)
C
Channel 2 not used
-196
(-321)
82
(180)
82
(180)
82
(180)
200
(392)
62
(144)
200
(392)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-8
(+18)
C
Channel 2 used
-196
(-321)
79
(174)
79
(174)
79
(174)
200
(392)
58
(136)
200
(392)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-8
(+18)
E, G
Switch output not used
-196
(-321)
83
(181)
83
(181)
83
(181)
200
(392)
62
(144)
200
(392)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-8
(+18)
E, G
Switch output used
-196
(-321)
78
(172)
78
(172)
78
(172)
200
(392)
58
(136)
200
(392)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-8
(+18)
K, L -196
(-321)
77
(171)
77
(171)
77
(171)
200
(392)
57
(135)
200
(392)
-40
(-40)
1)
-40
(-40)
1)
-40
(-40)
1)
-196
(-321)
-8
(+18)
1) -50 °C (-58 °F) for ordering feature 580 ("Test, Certificate") = JN ("Ambient temperature transmitter -50°C/-58°F")
Storage temperature
–40 to +80 °C (–40 to +176 °F)