DRAFT
Micropilot FMR51, FMR52
Endress+Hauser V. 1, Rev. 8, 4-10-2012 35
Installation
Installation conditions Mounting position
A
1 2
3
A0016882
• Recommended distance
A from wall to outer
edge of nozzle: ~ 1/6 of tank diameter.
Nevertheless the device should not be installed
closer than 15 cm (5.91 in) to the tank wall.
• Not in the center (2), as interference can cause
signal loss.
• Not above the fill stream (3).
• It is recommended to us a weather protection
cover (1) in order to protect the device from
direct sun or rain.
Vessel installations
A0018944
Avoid any installations (limit switches, temperature
sensors, braces, vacuum rings, heating coils, baffles
etc.) inside the signal beam. Take into account the
beam angle (® ä 38):