Installation Guide

Page 11
WALK-IN TUB MANUAL
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 866-633-4882 • Fax 866-560-1060
DRAIN CONNECTION
To ensure safe transit for your walk-in tub, the overflow drain components are not connected to the unit during the
process of production. The following instructions are provided for installation purposes:
Your walk-in tub is supplied with a 1 ½” drain pipe overflow.
1. The open and close valve with the turn knob should be attached to the unit at the 1 ½” pre-drilled opening in
the wall of the unit from the outside.
2. The opposite end of the overflow should be attached to the 1 ½” pre-drilled opening in the foot well of the unit
from the underside.
3. The chrome turn knob and the drain cover should be attached to the appropriate ends of the overflow drain
from the inside of the unit.
4. Place the chrome cap with stem into the floor drain to close off the opening.
5. The cable attached to the turn knob of the overflow is also connected to a lever inside the floor drain which
allows the drain to be opened or closed.
6. Once the components of the overflow are secured into place, turn the overflow knob to the open and closed
position to ensure proper function. The cap and stem will move up and down, opening and closing the drain
(Figure 1).
overflow
drain cable
drain cable
drain
drain shoe
drain tee
Parts Provided
Not Provided
FIGURE 1