Installation and Operating Manual Keyboard for Fastrax Dome Video Cameras EDC-KBDM3
Contents Safety Instructions.....................................................................................................................................................................................................................3 1. Introduction.....................................................................................................................................................................................................................3 1.1 Features........................
Safety Instructions • Read these safety instructions and the operation manual first before you install and commission the unit. • Keep the manual in a safe place for later reference. • Protect your unit from contamination with water and humidity to prevent it from permanent damage. Never switch the unit on when it gets wet. Have it checked at an authorized service center in this case. • Never operate the units outside of the specifications as this may prevent their functioning.
up to 255 Multiplexer up to 8 alarm inputs up to 99 DVR (Sensor) up to 4 alarm outputs (Siren) (Flashing light) up to 254 cameras J-box J-box Master Keyboard J-box Slave Keyboard #1 J-box Slave Keyboard #2 Slave Keyboard #3 Figure 1: Typical System Configuration 2. Installation and Configuration 2.
2.
2.4 RS-485 End of Line Termination The first and last devices in an installation must have the data line terminated by setting the DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1.2km. Cable for communication Termination ON Termination ON 1.2km Repeater/Splitter Input termination ON Output termination ON Termination ON 1.
2.5 Dip Switch Setting Termination and Master/Slave: Set the switches according to your configuration. Figure 4: DIP switches setting NO. 1 2 3 4~6 7 8 SETTING On Off On Off On Off DESCRIPTION DOME1 Port Termination Mux/Slave Termination DOME2 Port Termination – (Reserved) On Slave Off Master On PAL Off NTSC 2.6 Quick Installation Procedure The dome camera must be installed by qualified service personnel in accordance with all local and federal electrical and building codes. 1.
2.7 Getting Started Once installed apply power to the KBD controller. The KBD controller will start a scanning the connected device according to configuration. When scanning is going and done, the following information is displayed on the keyboard controller’s LCD SCANNING DOME : 009 FOUND. SCAN DATA1–254:001.003.004.033 049. SCAN DATA2–254:007.008.009.
2.8 Recommended Installation Examples 1.
2. Single user system with two Multiplexers (31 cameras max) J-Box Dome RS-485(+) DOME 1 + RX+ (TX+) RS-485(-) DOME 1 - RX- (RX-) RS-485 Dome control cable (max. 1.
3. Multi user system with two Mux configuration J-Box Dome RS-485(+) DOME 1 + RX+ (TX+) RS-485(-) DOME 1 - RX- (RX-) RS-485 Dome control cable (max. 1.
4. Multi user system with Multiple Mux configuration RS-485 Dome control cable (max. 1.
2.9 Multiplexer Configuration Examples Press CTRL + MENU to call the Main menu Go into MAIN MENU –> NETWORK –> MUX CONFIGURATIONS After setting up Cam 001 Press the ON Key to fill the rest of the camera fields automatically.
Example 2: Multi/Single user system with 28~31 Cameras and two Multiplexers Dome ID 01 –> 02 –> 03 –> 04 –> 05 –> 06 –> 07 –> 08 –> 09 –> 10 –> 11 –> 12 –> 13 –> 14 –> 15 –> 16 –> Mux 01 Cam 1 Cam 2 Cam 3 Cam 4 Cam 5 Cam 6 Cam 7 Cam 8 Cam 9 Cam 10 Cam 11 Cam 12 Cam 13 Cam 14 Cam 15 Cam 16 Aux 4 Aux 3 Aux 2 Aux 1 Main Keyboard Slave Keyboard 1 Slave Keyboard 2 Slave Keyboard 3 Master KBD controller ID 17 –> 18 –> 19 –> 20 –> 21 –> 22 –> 23 –> 24 –> 25 –> 26 –> 27 –> 28 –> Mux 02 Cam 1 Cam 2 Cam 3 Cam 4
Example 3: Multi/Single user System with 48 Cameras and 4 Multiplexers Dome ID 33 –> 34 –> 35 –> 36 –> 37 –> 38 –> 39 –> 40 –> 41 –> 42 –> 43 –> 44 –> 45 –> 46 –> 47 –> 48 –> Dome ID 17 –> 18 –> 19 –> Mux 03 Cam 1 Cam 2 Cam 3 Cam 4 Cam 5 Cam 6 Cam 7 Cam 8 Cam 9 Cam 10 Cam 11 Cam 12 Cam 13 Cam 14 Cam 15 Cam 16 Aux 1 Aux 2 Aux 3 Aux 4 Mux 02 Cam 1 Cam 2 Cam 3 Cam 4 Cam 5 Cam 6 Cam 7 Cam 8 Cam 9 Cam 10 Cam 11 Cam 12 Cam 13 Cam 14 Cam 15 Cam 16 Aux 1 Aux 2 Aux 3 Aux 4 Mux 01 Cam 1 Cam 2 Cam 3 Cam 4 Cam 5 Ca
Example 4: Multi/Single User system with 64 Cameras and 5 Multiplexers Dome ID 49 –> 50 –> 51 –> 52 –> 53 –> 54 –> 55 –> 56 –> 57 –> 58 –> 59 –> 60 –> 61 –> 62 –> 63 –> 64 –> Dome ID 33 –> 34 –> 35 –> Mux 04 Cam 1 Cam 2 Cam 3 Cam 4 Cam 5 Cam 6 Cam 7 Cam 8 Cam 9 Cam 10 Cam 11 Cam 12 Cam 13 Cam 14 Cam 15 Cam 16 Aux 1 Aux 2 Aux 3 Aux 4 Dome ID 17 –> 18 –> 19 –> Mux 03 Cam 1 Cam 2 Cam 3 Cam 4 Cam 5 Cam 6 Cam 7 Cam 8 Cam 9 Cam 10 Cam 11 Cam 12 Cam 13 Cam 14 Cam 15 Cam 16 Aux 1 Aux 2 Aux 3 Aux 4 Mux 02 Cam 1
2.10 Keyboard Configuration Menu Setup The user needs to setup network, passwords and special functions such as uploading and downloading programmed data from the dome cameras. Key operation example CTRL + MENU : Press and hold down the CTRL key and press MENU key. 1 + CAM : Press 1, CAM keys sequentially. CTRL + Joystick : Press and hold down the CTRL key while manipulate Joystick handle. Special key action in the Menu PGM key : Press PGM key to save and exit to previous menu.
CONFIGURATION MENU CONFIGURATION KEY BEEP : ON BACKGROUND VIDEO : OFF VIDEO IN MENU : ON AUTO KEY-LOCK : OFF LCD POWER SAVE : 05 MIN. CHANGE USER PASSWORD CHANGE ADMIN PASSWORD RESCAN DOME SAVE AND EXIT Configuration Setup Screen Key Beep When set to ON, the KBD controller’s internal speaker will sound when you press key.
CHANGE ADMIN PASSWORD CURRENT PASSWORD : XXXX NEW PASSWORD : YYYY CONFIRM PASSWORD : YYYY Change Administrator Password Screen This screen allows you to change administrator password. Password can be 4 digits. Factory Default setting is 9999. Log on Administrator level allows all rights of operation, setup, and program. NOTE: If you forget your own password, contact service personnel or distributor.
COMMUNICATIONS PORTS PORT DEFINITIONS DOME1 DOME2/DVR MUX/KBD DVR/AUX ALARM/AUX SAVE AND EXIT : : : : : DOME DOME DUPLEX NONE NONE Port Definitions Setup Screen This screen allows you to select what kind of device will be connected on the port of J-BOX.
ALIAS PRESET MENU ALIAS PRESET MENU PAGE : 001 NO. DOME ID ALARM NO INPUT 0001: 001 --- --0001 NO 0002: 002 --- --0002 NO 0003: 003 --- --0003 NC 0004: ----- ------0005: ----- ------0006: ----- ------0007: ----- ------0008: ----- ------ON : AUTO OFF:DEL. SAVE:PGM ESC Alias Preset Menu Setup Screen This screen allows you to set the KBD controller’s internal alias preset, each alias preset can have 3 dome cameras’ position. You can execute this function when alarm signal is detected or press No. + ALRM.
This screen allows you to set up each Slave KBD controller On or OFF. Slave ID No. When set to ON, Slave KBD controller’s user can operate the unit which is connected Master KBD controller.
TIME & DATE TIME & DATE DISPLAY DATE/DAY MONT YEAR HOUR MINUTE SAVE AND EXIT : ON : 29 THR : JAN : 2004 : 15 : 37 Time & Date Setup Screen This screen allows you to set the KBD controllers’ Time & Date. Display: When set to Off, the KBD controller will hide the time. ALARM MENU ALARM MENU ALARM CHECK ALARM BEEP ALARM DELAY ALARM BOX SAVE AND EXIT : ON : ON : LATCH Alarm Menu Screen This screen allows you to set up the actions KBD controller will take when there is an alarm condition.
ALARM SCHEDULE ALARM SCHEDULE PAGE : 01 CAM ALARM AUX MACRO 002 12345678 64 8 --– – – – --– – – – --– – – – 064 – 2---56 – 8 – --– – – – --– – – – --– – – – ON : INS. OFF : DEL. PGM ESC Alarm Schedule Setup Screen Alarm Schedule has 8 pages. All 8 alarm inputs of 64 dome cameras can be used to activate programmed Macro. Cam Camera to be relayed to the alarm box Alarm 1, 2, 3 ~ 8 – Select alarm Input to be relayed. Aux 1, 2, 3 ~ 64 – Relay Output No. of alarm box.
SCHEDULE SCHEDULE MACRO TABLES WEEKLY SCHEDULE ANNUAL SCHEDULE NIGHT SHOT SEQUENCE EXIT Schedule Menu Screen MACRO SETUP MACRO TABLES MACRO 1 MACRO 2 MACRO 3 MACRO 4 MACRO 5 MACRO 6 MACRO 7 MACRO 8 EXIT Macro Table Screen 8 MACRO can be programmed in this menu, select MACRO No. to be programmed. Automatic functions to be executed by No. + CTRL + MACRO or activated by alarm and its programmed schedule.
WEEKLY SCHEDULE MACRO 01 08 07 01 –– –– –– –– ON : INS. WEEKLY SCHEDULE TIME DAY 17 : 05 EVERY DAY 03 : 00 SUNDAY 08 : 30 MON-FRI 11 : 05 SAT-SUN – – – – – – – – – – – – – – – – OFF : DEL. PGM ESC Weekly Schedule Setup Screen This screen allows you to set weekly schedule to execute Macro command. Macro MACRO No.
This screen allows you to schedule that Night Shot mode is activated at programmed time. Night shot When set to ON, the dome camera of which night shot mode is global will change the night shot mode at programmed time.
2.11 Install with Standalone DVR Series Wire Connection DOME R(T)X+ R(T)X– JUNCTION BOX DOME 1 + DOME 1 – DVR TX+ TX– JUNCTION BOX DOME 2 + DOME 2 – PTZ control from DVR Figure 9: DVR Connection diagram DVR1 or DVR2 can be set by following method though the menu system and screen are different. If user wants to connect with DVR, proceed as the following order: 1. Connect RS-232 cable between RS-232 Port of DVR and DVR port of the J-box.
5. How to setup DVR A. Switch the DVR on. B. Press the Menu button. Input password according to the instruction. (Factory setting is 4321) C. If the below screen is appeared, set „Quick Setup” to „Off”. D. Press „OK”, and the below screen will be appeared. E. Select „System Information” on the system menu and change UNIT ID.
F. Select „Camera” on the Device menu. Unit ID should be 1 up to 99. Unit ID is not allowed number „0”. G. Set „PTZ Device” and „ID” of the dome camera. Select RS232/RS485 after PTZ is installed, and then set-up as below table. RS-232/RS-485 Baud Rate Parity Data Stop Usage RS-232 9600 None 8 1 Remote Control RS-485 9600 None 8 1 PTZ Control 6. After setting Unit ID, Camera, and RS-232/RS-485, installing dome camera is basically completed.
3. Operation 3.1 Keyboard Lock/Unlock When the user leaves the control desk, he may wish to lock the keyboard controller to prevent unauthorized use. Pressing 777 + ENTR will lock the keyboard controller. Pressing 777 + ENTR while the keyboard is locked will open the password screen. If the correct password is entered, the keyboard controller will return to normal operation. If the power is turned off and on while the keyboard is locked, it will ask for the password.
3.2.2 Triplex Setup Press key double of the multiplexer to enter the Main Menu. Enter the Unit Setup using Network Type and SET key of the multiplexer. RS 485 Baud Rate 9600 bps Unit address 001 ~ 128 Protocol B1 • Selecting camera (No. + CAM and PREV or NEXT) With these selections, the keyboard controller has full control of the selected camera if it is a dome camera. Viewing Full Screen (Multiplexer video input No.
3.3 Camera Control Manual Focus CONTROL Press the keyboard buttons Far and Near to manually focus the camera. When the ZOOM handle of the joystick is twisted slightly, the camera will return to Auto Focus mode Manual Iris CONTROL Press the keyboard buttons Open and Close to manually open and close the iris. Move the joystick slightly to return to Auto Iris mode. Zoom CONTROL Twist the joystick to zoom in and out.
3.4 Summary Of Keyboard Controls Keys for Dome Camera Function Key Label Descriptions Camera selection 0..9 + CAM Displays the selected camera on the spot out of the multiplexer and allows the camera to be controlled by the keyboard controller, if the selected camera is a dome camera. Function number selection with function keys. (e.g. 1 + CAM, 3 + TOUR, 5 + SCAN, 6 + PRST) Cancel ESC Alarm ALRM Cancels current inputs. Exits from currently running functions or menu, error status, etc.
Keys for Multiplexer Function Full Screen Key Label No. + MAIN Descriptions Puts the multiplexer in Full-Screen Mode of the selected camera No. PiP PIP Picture-in-Picture mode 2 x 2 Display 2X2 Displays view of four cameras. The remaining cameras can be sequenced in the lower-right window. 3 x 3 Display 3X3 Displays view of nine cameras. The remaining cameras can be sequenced in the lower-right window. 4 x 4 Display 4X4 Displays view of 16 cameras in 1/16-size pictures.
Function Key Label Descriptions Toggle between different display formats. The available formats are: full, 4x4, 3x3, 2x2 and PIP. Display Mode Select a highlighted item or completes an entry that you have made. Enter CTRL + 1 ~ 7 , 9 Display Mode Go Last CTRL + Go First CTRL + X times Backward play Nr. + X times Forward play Nr. + PC DVR screen mode Go last in PC DVR Go first in PC DVR Fast play at x (No.
5. Short Cut Key Short Cut Key Function PRST Pop up preset setup menu TOUR Pop up guard Tour setup menu PTRN Pop up Pattern setup menu SCAN Pop up Auto Scan setup menu No.+ PGM+PRST Store the current view at the selected number No.+ PGM+TOUR Pop up tour setup menu at the selected number No.
5. Specifications Model EDC-KBDM3 Art. No. 74092 Integrated Monitor TFT/LCD monitor (5”/12.7cm screen size) Video Input 1Vp-p, CVBS, 75ohms Adjustment Brightness and colour Site Control (direct mode operation) Keys select cameras and monitors, operate presets, patterns, auxiliaries, and sequences.
Art. No.
5 7.
APPENDIX 1 Control the other camera (available Version 3.0 and over) When you want to control to the camera of Spectra III™ SE series with the FASTRAX camera, refer to the following sentence. Example of the system configuration ID 01 05 07 Protocol F2E F2E Pelco-D 09 10 F2E Pelco-P J-Box MAIN MENU Press CTRL + MENU to enter the KBD controller main menu. You will see the following menu.
CAMERA SETUP CAMERA SETUP PAGE : 001 CAM PROTOCOL PORT BAUD 001 F2E DOME1 9600 005 F2E DOME1 9600 009 F2E DOME1 9600 --- - - - --- - - - --- - - - --- - - - --- - - - OFF : DEL PGM : SAVE ESC : EXIT When the keyboard has that the alarm option is ON, at the first power on, the camera setup displays as above after the keyboard checks the camera automatically. At this time, the F2E protocol could not be changed. To add the other camera, 1. Position the cursor at the CAM field below 009, the dash blinks. 2.
Keys for other Camera Function Key Label Descriptions Camera selection 0..9 + CAM Select the camera to be controlled by the keyboard controller. Previous PREV Allows the previous dome camera to be controlled manually. Next NEXT Allows the next higher number dome camera to be controlled manually. Recalls preset The presets are numbered 1-32, 35-82, and 100-150 of the Spectra III SE system. (Refer to the manual of the dome camera) Call Preset position Program the preset 0..9 + PRST No.
APPENDIX 2 Control the DVR for the Version 3.1.0 and over (available Version 3.0 and over of the keyboard) Installation of the DVR4 protocol when one DVR is used NOTE: When you set the protocol to DVR4, the keyboard operates as the DVR’s keyboard only. DVR Connection Diagram When you control the PTZ camera by the DVR, follow as below. 1. Connect RS-232 cable between RS-232 Port of DVR and DVR port of the J-box. (This connection enables DVR control remotely from KBD controller) 2.
6. How to setup DVR: D. Switch the DVR on. E. Enter the Menu according to the DVR’s instruction manual. F. G. Confirm matching the setup of RS-232 with the keyboard. Ex: Baud Rate:9600, Data Bit:8, Stop Bit:1, Parity:None) H. Change the Remote Control to “Remote Control2” in the devices menu. I. J. Confirm matching the setup of RS-485 of the PTZ menu with PTZ cameras. K. Set the PTZ menu according to PTZ cameras.
Installation of DVR4 protocol when many DVR use When you control PTZ cameras on many DVRs, you need RS-232 to RS-485 converter. PTZ cameras are connected to RS-232 to RS-485 converter by the RS-232 port of the DVR and the keyboard is connected through the RS-485 port of the DVR. Follow as below. 1. Connect RS-485 cable between RS-485 Port of DVR and the DOME1 port of the J-box. 2. Connect RS-485 cable to the RS-485 Ports of DVRs. 3.
Keys for Dome Camera Function Camera selection Key Label 0..16 + CAM Descriptions Displays the selected camera number Cancels current inputs. Exits from currently running functions or menu, error status, etc. Cancel ESC Alarm ALRM No Action ON No Action Relay OFF OFF No Action Previous PREV No Action Next NEXT No Action Home HOME Immediately calls Home function.
Keys for DVR Function Key Label Descriptions ID Selection DVR ID Selection (e.g. 1 or 2 + DVR) PTZ Open a Pan/Tilt/Zoom screen which allows you to control properly configured cameras. Play/Pause Play recorded data / Pause playing Rewind Play video backward at high speed. Pressing the button again toggles the playback speed from and . Fast Forward Play video forward at high speed.