Installation and Operating Manual Fastrax III 1/4” Day/Night High Speed Dome Camera EDC-3182, EDC-3262, EDC-3351, EDC-3362
Contents Safety Instructions / Maintenance............................................................................................................................................................................................. 3 1. Introduction..................................................................................................................................................................................................................... 4 1.1 2. 3. Features........................
Safety Instructions / Maintenance • Read these safety instructions and the operation manual first before you install and commission the camera. • Keep the manual in a safe place for later reference. • Protect your camera from contamination with water and humidity to prevent it from permanent damage. Never switch the camera on when it gets wet. Have it checked at an authorized service center in this case. • The unit should be protected against excessive heat, dust and vibration.
1. Introduction 1.1 Features The Fastrax III dome camera and the keyboard controller make up the building blocks for any surveillance/security system. Using multiple Keyboard Controllers and multiple dome cameras, no place is too large for monitoring. Extensible and flexible architecture facilitates remote control functions for a variety of external switching devices such as multiplexers and DVRs. • Built-in optical power zoom camera with True Night Shot function • 240 Preset positions.
Alarm Input (up to 8) Alarm Output (up to 4) up to 255 multiplexers up to 99 DVRs up to 254 cameras including 64 alarm modes Figure 1 - Typical System Configuration push bubble ring ass’y remove camera window screw push Remove window Assemble bubble ring ass’y Figure 2 - Optional Assemble bubble ring ass’y NOTE: It is recommended to remove camera window for improving picture quality when you assemble bubble ring ass’y.
2. Installation and Configuration 2.1 Package Contents The package contains the following: 1x Fastrax III (Dome Camera) 1x Bubble ring (optional) 1x Instruction manual (this document) 3x Assembly screws for attaching Fastrax III 3x Plastic anchor 1x 10Pin Connector 2x 12Pin Connector CAUTION: Be sure to have caution labels (E version only) on both body and base of the camera. Different version will not support alarm input and output.
2.
SW1: Termination switches SW2: Fail-Safe Network Addresses (ID) and protocol selection switches Figure 5 - Layout of Switches 2.3 Setting Dome Camera Termination The device which is connected at end of line, whether it be a dome camera or keyboard controller, must have the cable for communication terminated by setting the appropriate DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1.2km.
2.4 Fail-safe Network When you control the dome by the other device not own keyboard, some error may be existed in the serial communication. The reason is caused by the other device without the fail-safe network. At this time, you solve the problem to set this DIP switch to ON of the nearest dome from the other device only.
2.5 Setting Dome Camera Address (ID) To prevent damage, each dome camera must have a unique address (ID). When installing multiple dome cameras using a multiplexer, it is suggested that the dome camera address matches the multiplexer port number. If you wan to set the address more than 999, you should connect the service provider. Example: Port 1 = Dome 1, Port 2 = Dome 2 ... Port 16 = Dome 16.
2.6 Setting Dome Camera Protocol If a dome camera is to be installed with a Fastrax keyboard controller, select the default protocol. Consult service personnel if a dome camera is installed with device other than a keyboard controller.
2.7 Connections • Connecting to the RS-485/-422 The dome camera can be controlled remotely by an external device or control system, such as a control keyboard, using RS-485 half-duplex, RS-422 full duplex or simplex serial communications signals. Connect Marked Tx+, Tx- to Tx+(Rx+) and Tx-(Rx-) of the RS-485 control system. If control system is RS-422, connect Rx+(Tx+), Rx+ (Tx-) and Rx+, Rx- of the dome camera to Rx+, Rx- and Tx+, Tx- of the control device respectively.
3. Program and Operation 3.1 Dome Camera Selection Before you program or operate a dome camera, you must select the dome camera by pressing the dome camera No. + CAM. Example: Pressing 1, 0 and CAM key sequentially will select dome camera 10. The selected dome camera ID will be displayed on the LCD monitor of the keyboard controller. 3.
3.4 Auto Scan (Shortcut: Scan) The Auto scan supports up to 17 programmed angles at user-programmable speeds.
10. Set „DWELL TIME”. 11. Select Save and Exit and push the Joystick to the right or press IRIS OPEN. Press ESC or IRIS CLOSE to exit the program without saving. Pressing the HOME key delete stored data at the angle field. To set the position using the preset position: a. Before entering the AUTO SCAN menu, select a preset position as a starting point for Auto Scan. Example: 2 + PRST and do step 1 to 4.
Follow steps below to store the Preset positions: 1. Press the PRST key to enter the preset menu directly. Or press the MENU key to display the main menu on the monitor. Scroll to preset and push the Joystick to the right. 2. Select the blank preset position to be stored by pushing the Joystick up, down, right, or left. 3. After selecting a blank position, press and hold CTRL. Use the Joystick to control the direction of the camera and lens. 4.
3.7 Tour (Shortcut: TOUR) There are 8 programmable Tours. Each Tour consists of up to 42 Preset positions, Patterns, Scans or other Tours (second-level). Using second-level tours, it can be expanded to over 300 functions in a single tour.
3.8 Pattern (Shortcut: PTRN) The Pattern feature records user control of the selected dome camera. Up to four 8 patterns can be stored and played back by pressing No.+ PTRN keys subsequently. NO. TITLE 01: P01 02: P02 03: P03 04: P04 05: P05 06: P06 07: P07 08: P08 TOTAL: PATTERN SETUP SEC 000 000 000 000 000 000 000 000 0000 (CTRL KEY) PERCENT 00.0% 00.0% 00.0% 00.0% 00.0% 00.0% 00.0% 00.0% 00.0% SAVE AND EXIT (ESC TO CANCEL) Follow steps below to program the Pattern: 1.
3.9 Alarm ALARM SETUP NO PRI FUN IN OUT HLD LATCH 01 1 001 NC OFF 03 OFF 02 2 A01 NO OUT1 03 OFF 03 1 – – – OFF OUT1 03 OFF 04 1 – – – OFF OUT4 03 OFF 05 1 – – – OFF OFF 03 OFF 06 1 – – – OFF OUT1 03 OFF 07 1 – – – OFF OUT1 03 OFF 08 1 – – – OFF OUT4 03 OFF DWELL: 03 RELAY OUT SETUP SAVE AND EXIT (ESC TO CANCEL) NO: Alarm input number PRI (priority): The lower number has higher priority. (0-8) FUN (function): Stored function number to be called by alarm.
3.10 Area Title Enter a specific name on programmed angle between START and END. For the screen below, when the camera points at an angle between 124.3° (PAN), 30.7° (TILT) to 359.5° (PAN), 45.4° (TILT), ABC will be displayed on the screen. AREA TITLE SETUP NUMBER: 01 TITLE: ABC START ANGLE: 124.3 END ANGLE: 359.5 SWAP: OFF 30.7 45.4 SAVE AND EXIT (ESC TO CANCEL) NUMBER: 01 - 16 TITLE: up to 12 characters SWAP: swap the start point for the end point 1.
PRIVACY AREA MENU (CTRL KEY) CONTROL NUMBER 001 354.8 344.8 3. Place the cursor at the title field. Twist the Joystick to enter the title edit mode. Follow the procedure of the auto scan above to edit titles. 4. To turn the stored zone On or Off, twist the Joystick handle or press Tele or Wide Key. 5. Set the method, „BLOCK” or „V.OFF (video off)” 6. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the program by pushing the Joystick to the right.
• FOCUS CONTROL FOCUS SETUP MODE: AUTO AF SENSITIVITY: LOW FOCUS LIMIT: 29CM SAVE AND EXIT (ESC TO CANCEL) MODE AUTO / MANUAL / ONE PUSH / CONSTANT MANUAL Use manual mode in normal use. AF SENSITIVITY NORMAL / LOW NORMAL: Use this option when shooting fast motion. LOW: FOCUS LIMIT Offers better focus stability. In low luminance conditions, Auto Focus stops operation even when brightness changes, enabling stable images of moving objects.
• AE CONTROL AE SETUP MODE: MANUAL SLOW SHUTTER: ––– IRIS: F5.
• LINE LOCK CONTROL LINE LOCK SETUP MODE: INTERNAL PHASE: 000 SAVE AND EXIT (ESC TO CANCEL) MODE INTERNAL / EXTERNAL PHASE Adjusts phase of picture with other cameras in EXTERNAL mode. (0~255) SAVE AND EXIT (ESC TO CANCEL) 3.13 Camera Menu, Type EDC-3351 (35x, Art. No.
• WB (White Balance) CONTROL WB SETUP MODE: AUTO R GAIN: 120 B GAIN: 100 SAVE AND EXIT (ESC TO CANCEL) MODE AUTO / MANUAL MANUAL: Control of R and B gain AUTO: Computes the white balance value output using colour information from the entire screen automatically (2800 to 8000K). RGAIN 0 ~ 255 BGAIN 0 ~ 255 RGAIN / BGAIN modes are controllable only in MANUAL Mode.
• AE CONTROL AE SETUP MODE: AE (DAWN) DSS LIMIT: 1/2 IRIS: AUTO GAIN: AUTO SHUTTER: 1/60 IRIS OFFSET: 106 IRIS PEAK: 016 BLC: OFF BLC LEVEL: 030 NIGHT SHOT: OFF WDR: OFF SAVE AND EXIT (ESC TO CANCEL) MODE AE / AE (DSS) / AE (DAWN) / AE (DARK) / IRIS PRIO / SHUTTER PRIO / AGC PRIO AE: Automatic Exposure (available motion detection).
AE mode DSS IR Remove WDR AE X O [Manual] O AE (DSS) O [auto] O [Manual] O AE (DAWN) O [auto] O [auto] : Hi sensitivity O AE (DARK) O [auto] O [auto] : Mid sensitivity O Shutter priority O [Manual] O [Manual] X IRIS priority X O [Manual] X AGC priority X O [Manual] X X: not available, O: available • LINE LOCK CONTROL LINE LOCK SETUP MODE: INTERNAL PHASE: 000 SAVE AND EXIT (ESC TO CANCEL) MODE INTERNAL / EXTERNAL PHASE Adjusts phase of picture with other cameras in EXTE
3.15 Dome Setup CONFIGURATION MENU LANGUAGE: HOME FUNCTION SETUP OSD DISPLAY VIEW ANGLE SETUP INITIALIZE DATA ORIGIN OFFSET DOME RESET SYSTEM MENU SYSTEM INFORMATION ENGLISH SAVE AND EXIT (ESC TO CANCEL) • LANGUAGE SETUP LANGUAGE • English, French, German, Italian, Spanish, Polish, Portuguese Select the language you want.
• OSD DISPLAY OSD DISPLAY SETUP CAMERA TITLE: DOMEID VIEW DIRECTION: OFF DOME OSD: ON AREA TITLE: OFF PRESET TITLE: CONSTANT FOCUS EXPOSURE: ON OSD POSITION SETUP SAVE AND EXIT (ESC TO CANCEL) CAMERA TITLE Up to 6 characters VIEW DIRECTION ON / OFF „ON” sets current direction as N (North) and the coordinate angle to 000. „OFF” hides the directional title. Every 90 degrees of clockwise rotation will change the title to E (East), S (South), W (West).
• VIEW ANGLE SETUP VIEW ANGLE SETUP PANNING RANGE FLIP: 90° TILT OVER ANGLE: ON SAVE AND EXIT (ESC TO CANCEL) FLIP OFF, 90°, 100°, 110°, 120°, AUTO [type EDC-3182 (Art. No. 74169), EDC-3262 (Art. No. 74170) and EDC-3362 (Art. No. 74161)] OFF: 90°, 100°, 110°, 120°: Allows the image to flip digitally when the camera moves over the setting angle vertically. AUTO: TILT OVER ANGLE The dome camera moves until 90° vertically.
• INITIALIZE DATA INITIALIZE DATA FACTORY DEFAULT ERASE PROGRAMMED DATA PRESET FOCUS DEFAULT EXIT (ESC TO EXIT) FACTORY DEFAULT Select the Factory Default to initialize the Data. FACTORY DEFAULT ARE YOU SURE ? CANCEL OK ERASE PROGRAMMED DATA Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to enter ON or OFF. If you desire to erase all data then select the Erase Run, otherwise press the ESC key to exit without erasing.
• ORIGIN OFFSET OFFSET SETUP (CTRL KEY) PAN OFFSET: 000.0 TILT OFFSET: 000.0 ENABLE: OFF SAVE AND EXIT (ESC TO CANCEL) This feature is useful to align a new dome camera exactly the same as the previously installed dome camera. Dome camera’s origin set and all data initialize option do not override offset values. Only the default set option in this menu will set the offset value to zero. This can be used to avoid ceiling obstructions.
MOTOR SETUP Motor Setup menu provides the pan and tilt speed of a camera. User can set the desired speed with twist the Joystick left or right. During operation, pressing 153 + ON will change the speed to the SLOW mode and pressing 153 + OFF will change the speed to the Normal mode. Holding and pressing CTRL and moving the joystick will operate with the TURBO speed mode.
• SYSTEM INFORMATION SYSTEM INFORMATION CAMERA TYPE: H/W VERSION: ROM VERSION: PROTOCOL: BAUDRATE: EXIT (ESC TO EXIT) xxxx Vx.xx Vx.xx xxxx 9600 The system information provides essential information about the dome camera if service is required. When you view this screen, you can determine the camera type, ROM version. The information on this screen cannot be modified. 3.
3.17 Motion Setup (Type EDC-3182, 18x, Art. No. 74169, EDC-3262, 26x, Art. No. 74170 and EDC-3362, 36x, Art. No. 74161) The motion detection function is available in the preset mode only. After you set the motion in any preset, when you call the preset with the motion, the motion detection operates. In the preset setup, you can set the motion setup as below.
3.18 Motion Setup (Type EDC-3351, 35x, Art. No. 74159) The motion detection function is available in the preset mode only. After you set the motion in any preset, when you call the preset with the motion, the motion detection operates. In the preset setup, you can set the motion setup as below.
4. Troubleshooting If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information. Problem Possible Solution No video Verify that power is connected to all pieces of equipment in the system. Verify that the power switches are in the ON position. Check the video connections.
5. Glossary Alarm Actions The assigned responses for the dome camera when inputs change from normal to abnormal states. The dome may run a Preset, Pattern, or have no assigned action for each of the four dome inputs. The dome may also send alarm states to the host controller for processing. See also Input and Normal Input State. Areas Programmed start and end points of the dome’s field of view around its pan axis. Each area is a part of a circular viewing area that extends around the dome.
6. Short Cut Key Short Cut Key Function PRST Pop up preset setup menu TOUR Pop up Tour setup menu PTRN Pop up Pattern setup menu SCAN Pop up Auto Scan setup menu NO.
7. Specifications Type Art. No. EDC-3182 EDC-3262 74169 74170 Series EDC-3362 74159 74161 eneo Fastrax III Video standard CCIR/PAL System Day & night Sensor size 1/4” Imager CCD, Sony ExView HAD Interline Transfer Synchronization Internal/AC line lock, phase adjustment via remote control Signal-to-noise ratio Sensitivity (at 50% video signal) EDC-3351 50dB 0.2Lux, at F1.2, 0.35Lux at F1.6, 0.2Lux at 1/3sec. shutter speed (F1.6) 0.02Lux at 1/3sec. shutter speed (colour), 0.
Type Art. No. Lens EDC-3182 EDC-3262 Horizontal angle of view Digital Zoom EDC-3362 74159 74161 74169 74170 F1.4 ~F75/4.1 ~73.8mm (18x optical, 12x digital zoom) F1.6 ~ F80/3.5 ~ 91mm (26x optical, 12x digital zoom) 4,1 mm - 73,8 mm 3.5-91mm 3.4-119mm 3.4-122.4mm 48° - 2,8° 54.2-2.2° 55.8°-1.7° 57.8-1.7° Aspherical technology Focal length EDC-3351 F1.4 ~ F170/3.4 ~ 119mm F1.6 ~ F75/3.4 ~ 122.
Accessories Art. No. Type Description 70449 NE-128 Voltage supply unit 230V/24VAC-5A, IP66 70527 NE-132/AC24V Power Supply Unit 230VAC/24VAC (1.0A) 74136 EDC-OPS-2/24V Pendant Mount Outdoor Dome Housing with Sunshield, Tinted Bubble 6.5”, 24VAC 74130 EDC-OPC-2/24V Pendant Mount Outdoor Dome Housing, Sun Shield, Clear Bubble 6.5”, 24VAC 74134 EDC-IPS-2/24V Pendant Mount Indoor Dome Housing with Tinted Bubble 6.
199 202 8. Dimensional Drawings R2.
eneo® is a registered trademark of Videor E. Hartig GmbH Exclusive distribution through specialised trade channels only. Videor E. Hartig GmbH Carl-Zeiss-Straße 8 · 63322 Rödermark/Germany Tel. +49 (0) 6074 / 888-0 · Fax +49 (0) 6074 / 888-100 Technical changes reserved. www.videor.com © Copyright by Videor E.