Operating instructions

50
1. Click „Configure to enter to the RS485 setting page (please refer to Change the System Setting – RS485
Setting). Select a Speed Dome device ID from the drop-down list on the Speed Dome Controller.
The Controller will display the corresponding ID.
2. Each of the ten buttons under ’Set’ is connected with a specific position and angle of either panning or tilting of
the camera. Click each button to activate its particular position and angle. Press the button under ’Preset’ to turn
the camera angle by angle in the set positions. Each of the ten buttons designated ’Go to’ can be clicked to view
the particular corresponding angle of the position in which it is set.
3. Select the connecting port. The RS-485 communication ports function as connectors when two or more units are
serially connected to an external control device.
4. Upon the buttons being clicked, a camera will move one short step only in any of the four designated directions.
5. Click the buttons to control the Focus setting on the Speed Dome Controller. Click „
+ button to focus far and click
the „ button to focus near.
6. Click the buttons to control the Zoom setting on the Speed Dome Controller. Click „
+ button to zoom in and click
the „ button to zoom out.
7. Upon the buttons being clicked, a camera will turn all the way, without stopping, in one of the four designated
directions.
8. Click the buttons to control the Aperture setting on the Speed Dome Controller.
6.1.7 Control the Speed Dome
Click the Pan/Tilt button on the home page to open the Speed Dome Controller.