Table 2.4.2. Menu item in ALARM-OUT Setup screen
Item Description
ALARM OUT
Select an alarm out number.
Available NO: 4ch (1)
SENSOR IN
Enable Alarm Out by Sensor up to 4 Inputs.
MOTION ON
Enable Alarm Out by Camera Motion up to 4 cameras.
VIDEO LOSS ON
Enable Alarm Out by Video Loss up to 4 cameras.
ALARM DURATION
Set the alarm dwell time from 5 to 60 seconds.
ERROR ALARM
Set the error type for the alarm activation. The options are
OFF, ALL, HDD ERROR and VIDEO LOSS.
2-4-2 Controller & PTZ Setup
To control the controller and PTZ functions of the camera, connect a controller to the RS-485 port.
①
①①
① Connect the RS-485 cables of Controller and PTZ camera to the RS-485 port on the rear panel.
②
②②
② Press SEL button or double click to enter the menu. Then Controller and PTZ menu screen is
displayed.
Figure 2.4.3. Controller and PTZ Control Setup Screen
Note: For speed dome cameras that support RS-485, connect them directly to the RS-485 port. If the
camera is controlled with RS-232C, use an RS-485 to RS-232C signal converter.
On the Controller and PTZ control setup screen, you can select or set the protocol type of the camera that
is the same as the one installed on the site. If the camera has a specific camera ID, select the camera ID
using the control button (◀ ▲ ▶ ▼).
The following options are available on the Controller and PTZ setup screen.
CHANNEL (channel number that the Controller and PTZ is connected to)
NAME (protocol type)
SPEED (19200, 14400, 9600, 4800, 2400)
ID (0-63)
Keyboard Controller Mapping Table