Instruction manual

11
It is required to perform factory reset in all daisy-chained MMXs and set up the system all over again
to complete the connections. The MMX system might not work properly when applying previously saved
settings to the MMXs after the factory reset. Refer to Factory Reset for details on the factory reset.
Option Switch
Set the switch to the On or Off position depending on the usage as follows:
No. Description ON (Upward) OFF (Downward)
1 ON/OFF Video signal format is NTSC. Video signal format is PAL.
2 END OF SLAVES The MMX is a slave MMX with the highest
ID number among all slave MMXs.
The MMX is a spot MMX.
The MMX is the only one MMX.
Other cases except when the switch is
set to the ON position.
3 MASTER MODE The MMX is a master MMX. The MMX is a slave MMX or spot MMX.
4 SPOT MODE The MMX is a spot MMX. The MMX is a master MMX or slave MMX.
The following is examples of the option switch settings in a master MMX, slave MMXs and spot MMXs.
When installing single MMX with the NTSC video signal.
MMD (ID) Option Switch
Master MMX [0]
MMD (ID) Option Switch
Master MMX [0]
When installing a master MMX and one slave MMX with the NTSC video signal.
MMD (ID) Option Switch
Slave MMX [1]