Read the owners manual carefully before installing the EN-DCMOTION.
Description
The EN-DCMOTION is a motion activated switch for 12 and 24 Volt systems for which a Passive Infra-red Detector is used. On the
LOAD output of the EN-DCMOTION a light bulb, or other load, of 12 or 24 Volt can be connected. The maximum load is 10 Amps
continues.
The EN-DCMOTION is designed for indoor use only. This could be for example cargo space of a truck, a bus or inside a ship. To
prevent over-voltage, under-voltage and overload the EN-DCMOTION possesses some protection functions.
Operation
The EN-DCMOTION switches the load as soon as motion is detected. If no motion is detected any more the
EN-DCMOTION switches o with a delay. The delay time can be set by way of an internal potentiometer.
This is done in steps of 5 seconds. The minimum delay time is 5 seconds and the maximum delay time is
60 seconds. Default is a delay time of about 30 seconds. The load will be disconnected 30 seconds after
the last motion is detected.
30
5 60
Installation
1. Connect the minus ( - ) of the load to the ( - ) LOAD output.
2. Connect the plus ( + ) of the load to the ( + ) LOAD output.
3. Connect the minus ( - ) of the battery to the ( - ) INPUT.
4. Connect the plus ( + ) of the battery to the ( + ) INPUT.
Should the lamp switch on after nishing the connection then the
probability is the INPUT and LOAD are interchanged or the plus and
minus connection of the INPUT are interchanged.
Warnings:
• The product should only be connected by skilled tters / mechanics, which are aware of the regulations for working
with high battery voltages.
• Use of bad material and / or too thin wires can damage the EN-DCMOTION.
• Live parts must not come into contact with the housing of the EN-DCMOTION.
• Do not open the EN-DCMOTION when the input voltage is connected.
• Always use fuses (of the correct value).
12 / 24 V
BATTERY
LAMP 12 / 24 V
EN-DCMOTION
LOADINPUT
Electrical Data Other technical details
Description Value
Auto 12 V / 24 V detection
Adjustable switch time 5 seconds to 60 seconds
Boot time, after overload 30 sec
Low Voltage delay 5 sec
Boot delay ± 30 sec
Detection angle 60°H - 60°V
Detection range 5 meter
Connector type screw
Dimensions L 76.5 * W 48.5 * H 30.0 (mm)
Weight 30 grams
Description 12 V 24V
Output current (continuously) 10A
Output current (peak) ± 70 A (max. 170 µs) @ 12 V
Over current (shut down) ± 14 A (after 5 seconds)
Low Voltage threshold 10.5 V 21 V
Boot Voltage after low Voltage 12.6 V 25.2 V
Current consumption (idle stage) 2 mA
Over Voltage dimming state threshold 16.0 V 32.0 V