Product Manual

Enerdrive ePOWER Inverter 600W 12V Owners Manual Rev: 1.5
Page 12
DC Under Voltage Warning: DC Input Voltage is low and is close to the under-voltage shutdown
limit. Check battery voltage or battery connection.
Over Temperature Shutdown: Reduce the AC load and provide more ventilation to the unit. Unit
will automatically restart when the internal temperature of the unit cools down.
DC Over Voltage Shutdown / DC Under Voltage Shutdown: Check the battery voltage. In the rst
30 seconds, AC Output will resume when battery voltage is within the unit’s operating range. If the
battery voltage shutdown condition is ignored, the unit will switch OFF completely after 30 seconds
AC Output Overload Shutdown: Check AC Load connected to the unit. AC Output is short circuited
or AC Power draw by the load is beyond the unit’s limit. The indicator and alarm will beep for approx
30 seconds before it switched OFF completely. Restart the unit using the green ‘On/O’ button is
required after the AC Load condition is corrected.
USB Port
With the inverter on, the USB port can provide up to 2.1A, 5V output. This can be use to charge 5V
USB powered devices.
Remote Switch (optional) Connection:
The unit comes with a Remote port and an optional ‘Remote Switch’ accessory (EN1104-REM) can be
used to turn unit On and OFF remotely. To install the ‘Remote Switch’, just connect the switch’s RJ12
plug to the RJ12 ‘Remote’ port located on the Front AC panel of the inverter. Please note polarity
when connecting the plug.
The Power On/O push button on the remote shares the same function as the green ‘On/O’
button on the main unit.
With ‘Power Save’ Function set to OFF, the ‘Power’ indicator will remain solid ON when AC Output
Power is available and will be OFF when the unit has shutdown.
With ‘Power Save’ Function set to ON, the ‘Power’ indicator will be ashing when AC Output Power
is available and will be OFF when the unit has shutdown.
AC Load on Power Inverter:
Although the Power Inverter can provide high surge power up to two times the rated output power,
some appliances may still trigger on the inverter protection system. A higher power inverter is
required for those appliances.