Battery Bank:
The use of deep cycle battery is highly recommended for power inverter application
For battery size, you need to identify how long you wish to operate the load(s). Enerdrive does
recommend that you purchase as much battery capacity as possible. See more on “Estimated Run
time and Load” in Section 6.
Please use 12V Battery Bank system for 12V DC Input Inverter (EN1106S-12V). Using 12V DC Input
Inverter on 24V Battery System will damage the inverter and may catch re.
Fuse or Circuit Breaker:
DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required.
Select a fuse or circuit breaker with 70A/16V minimum rating for the 12V DC Input Inverter.
Based on the size of the battery bank chosen, determine the overall short circuit current rating of
the battery bank from the battery manufacturer. The fuse or circuit breaker chosen has to be able
to withstand the short circuit current that may be generated by the battery bank.
DC Input Cable:
Use of low resistance wire is required for all the DC connections between the inverter and the
battery bank.
Use minimum 16mm
2
cable with a maximum length of 1.5m for 12VDC inverter.
ePOWER Inverter Installation:
Choose an appropriate mounting location.
For indoor use, the orientation of the unit can be mounted in any direction except with the DC
Input panel facing downwards.
For RV installation, the unit has to be mounted horizontally.
Use mounting template below to mark the positions of the mounting screws.
Drill the 4 mounting holes and place the inverter in position and fasten the inverter to the mounting
surface.