Product Manual

Page 9
184 mm
162 mm
ePOWER Inverter DC Input Connection:
CAUTION
Reversing the DC Input terminal will damage the unit and cannot be repaired. Damage caused by reverse
polarity connection is not covered by the warranty.
Hardwired Direct Connection:
Make sure the main fuse is not connected or breaker is switched o.
Attach a positive (+) DC terminal (red) cable on the power inverter.
Attach a negative (-) DC terminal (black) cable on the power inverter.
Tighten the nut on each DC terminal.
Connect the other end of the positive DC input cable to one of the terminals of the fuse holder or
circuit breaker switch.
Connect a DC positive input cable between the other terminals of the fuse holder or circuit breaker
switch to the battery positive terminal.
Connect the DC negative cable from the inverter to the Negative BUS of your DC System.
Install the selected fuse to the fuse holder or switch on the circuit breaker.
Unit is ready for use.
CAUTION
Please be sure all the connections are tight before the use of the unit.